gefran 1600 Manual De Uso página 25

Ocultar thumbs Ver también para 1600:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
Hrd
Hardware configuration
Auxiliary input
hrd. 1
installation, digital
inputs, serial
interface.
Timer and multiset
enabling
Installation of
hrd. 2
relay, logic
outputs
MAIN, AL1,
AL2, AL3,
and analogue
outputs W1,
W2
hrd. 3
0
(trl
Control type
[0...78]
43
s. S . t .
Start / Stop Timer
-
r. t .
Reset Timer
--
(0 ... 15)
hrd.1
Aux
Logic
Logic
analogue
input 1
input 2
input
(IN1)
(IN2)
0
1
x
2
x
3
x
x
4
x
5
x
x
6
x
x
7
x
x
x
8
9
x
10
x
11
x
x
12
x
13
x
x
14
x
x
15
x
x
x
+16 to enable the Timer function
+32 to enable the Multiset function (2SP)
+64 to enable the Multiset function (4SP)
hrd.2
OUT 1
OUT 2
OUT 3
(relay, logic) (relay, logic) (relay, logic) (relay, logic)
0
1
x
2
x
3
x
x
4
x
5
x
x
6
x
x
7
x
x
x
8
9
x
10
x
11
x
x
12
x
13
x
x
14
x
x
15
x
x
x
+ 16 to enable analogue output W1
+ 32 to enable analogue output W2
+ 64 to invert state of LEDs compared to state of output
Non significant
function
CtrL
Control type
0
P heat
1
P cool
2
P heat / cool
3
PI heat
4
PI cool
5
PI heat / cool
6
PID heat
7
PID cool
8
PID heat / cool
9
ON-OFF heat
10
ON-OFF cool
11
ON-OFF heat / cool
12
PID heat + ON-OFF cool
13
ON-OFF heat + PID cool
14
PID heat + cool with relative gain
(see C.MEd parameter)
Selection of derivative action
sampling time:
+ 0
sample 1 sec.
+ 16 sample 2 sec.
+ 32 sample 8 sec.
+ 64 sample 240 msec.
Note: LbA alarm is not enabled with
ON/OFF type control
0
from enabled digital input
1
from AL1 ON
2
from AL2 ON
3
from AL3 ON
4
from ALHB ON
5
from serial line (address 0049H, bit 0)
6
from serial line (address 0049H, bit 1)
7
from keys
+8 inverse action
+16 Autoreset enabled (Stop = program reset)
(only for _S.S.t. parameter)
• Hrd
sens
probe type for
Serial
interface
x
x
x
x
x
sns. 2
Selection of probe
x
type for aux input
x
x
OUT 4
al. n r
Select number of
enabled alarms
x
x
x
x
x
x
x
x
butt
Function of M/A
but. 2
d. i . f . 1
Function of digital
d. i . f . 2
Function of digital
disp
25
SEnS
Probe type for main input
Selection of
0
Thermocouple (TC)
1
Resistance Thermometer (RTD)
main input
2
Thermistor (PTC)
3
Voltage 0...50mV / 10...50mV
4
Current 0...20mA / 4...20mA
5
Voltage 0...10V / 2...10V
6
Custom 10V
7
Custom max 50mV
+ 8 to enable main input curve 4 point correction
(alternative to custom linearization).
See description in "Main Input Correction
Function" section.
+16 to disable averaging filter on sampled
value (available from software release 3.05)
Note: scale selection with "tYPE" code in InP
SnS.2
Signal
0
0 ... 1V
1
0.2 ... 1V
2
0 ... 10V
3
2 ... 10V
4
0 ... 20mA
5
4 ... 20mA
6
Potentiometer
7
CT 50mA
+8 to disable averaging filter on sampled value
(available from software release 3.05)
AL.nr
Alarm 1
0
disabled
1
enabled
2
disabled
3
enabled
4
disabled
5
enabled
6
disabled
7
enabled
+ 8 to enable HB alarm
+ 16 to enable LBA alarm
b u t t
0
No function (key disabled)
1
MAN / AUTO controller
2
LOC / REM
3
HOLD
4
Start / Stop selftuning
keys: "*"
5
Start / Stop autotuning
6
Set / Reset outputs Out 1... Out 4
7
Alarms memory reset
8
SP1 / SP2 Selection
9
Integral contribution instantaneous
zero setting
10
Start / Stop Timer
(se S.S.t. = 7)
11
Reset Timer
(se _rt = 7)
+16 disable function in configuration menu
Non significant
0
function
d.i.F.1, d.i.F.2
0
No function (disabled input.)
1
MAN / AUTO controller
2
LOC / REM
3
HOLD
input 1 (IN1)
4
Start / Stop timer
5
Reset timer
6
Software on/off
7
Alarms memory reset
SP1...SP2 (2SP) Selection
8
input 2 (IN2)
SP1...SP4 – bit Lo Selection
9
SP1...SP4 – bit Hi Selection
+ 16 for inverse logic input
+ 32 to force logic state 0 (OFF)
+ 48 to force logic state 1 (ON)
diSP
Lower display (SV) function
0
SSP - setpoint enabled
(*)
1
InP.2 - aux input
Defining SV
(*)
2
Control output value
display function
(*)
3
Deviation (SSP - PV)
(*)
8
Visualisation of current time on PV
display and tS time on SV
display
+ 4 Timer in start
(*)
~
Alarm 2
Alarm 3
disabled
disabled
disabled
disabled
enabled
disabled
enabled
disabled
disabled
enabled
disabled
enabled
enabled
enabled
enabled
enabled