• To prolong the original appearance, clean with clear water and a soft damp cloth only.
• Do not use paints, solvents, or other chemicals on this light fixture. They could cause a premature deterioration of the
finish. This is not a defect in the finish and will not be covered by the warranty.
• Do not spray with hose or power washer.
SYMPTOM
POSSIBLE CAUSE
Lights will not
1.
Light switch is turned off.
come on.
2.
Light bulb is loose or burned out.
3.
Fuse is blown or circuit breaker is turned off.
4.
Daylight turn-off is in effect.
5.
Sensor not detecting movement.
6.
Incorrect circuit wiring, if this is a new installation.
Lights come on in
1.
Light control may be installed in a relatively dark location.
daylight.
2.
Light control is in TEST.
Lights come on for
1.
Light control may be sensing small animals or automobile
no apparent reason.
traffic.
2.
Sensitivity is set too high.
Lights stay on
1.
The sensor may be picking up a heat source like an air vent,
continuously.
dryer vent, or brightly painted, heat-reflective surface.
2.
Light control is in Manual Mode.
3.
Sensitivity is set too high.
Lights flash on
1.
Light control is in the TEST mode and warming up.
and off.
2.
Heat being reflected from other objects may be affecting the
sensor.
Seasonal Temperature Changes – The closer the surrounding temperature is to a person's body heat, the less sensitive the sensor will appear. The greater
the temperature difference, the more sensitive the sensor will appear. The SENS control might need to be readjusted toward MIN or MAX as the outside
temperature changes for the different seasons. This is a normal part of the light sensor's operation.
Range ................................................................Up to 30 ft. (9.1 m) [varies with surrounding temperature]
Sensing Angle....................................................Up to 150°
Sensor Aiming Adjustment Angle ....................90°
Electrical Load ..................................................Up to 60 Watt Maximum Incandescent
Bulb Type ..........................................................Medium Base, Type "A", 60 Watt Maximum
Sensor Capacity .................................................Up to 500 Watt (4.1 A) Maximum Tungsten
Power Requirements ..........................................120 VAC, 60 Hz
Operating Modes ..............................................TEST, AUTO, and MANUAL MODE
ON-Timer .........................................................1, 5, 10 minutes
Test Timer .........................................................5 Seconds
Manual Mode Timer .........................................Dusk-to-Dawn
All manuals and user guides at all-guidesbox.com
CARE AND MAINTENANCE
TROUBLESHOOTING GUIDE
SPECIFICATIONS
8
SOLUTION
1.
Turn light switch on.
2.
Check bulb and replace if burned out.
3.
Replace fuse or turn circuit breaker on.
4.
Recheck after dark.
5.
Re-aim the sensor to cover desired area.
6.
Verify wiring is correct.
1.
The fixture is operating normally under these conditions.
2.
Set control switch to 1, 5, or 10 minutes.
1.
Re-aim sensor. Reduce sensitivity.
2.
Reduce sensitivity.
1.
Re-aim sensor. Reduce sensitivity.
2.
Switch to Auto.
3.
Reduce sensitivity.
1.
Flashing is normal under these conditions.
2.
Re-aim sensor. Reduce sensitivity.