Peavey PV 6500 Manual De Operación página 20

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
Back Panel
POWEr SWItCH
32
This is the main power switch.
FuSE
33
This is the main safety fuse for the AC line voltage. Only
replace with a fuse of the exact type and rating. If the
fuse continues to open, do not over fuse. Take the unit
to an authorized Peavey service center.
NOtE: If the main aC voltage is changed, the fuse must
also be changed to one of the appropriate rating for
the voltage you are switching to.
aC POWEr INLEt
34
This is the receptacle for an IEC line cord, which pro-
vides AC power to the unit. Connect the line cord to this
connector to provide power to the unit. Damage to the
equipment may result if improper line voltage is used.
(See line voltage marking on unit).
Never break off the ground pin on any equipment. It
is provided for your safety. If the outlet used does not
have a ground pin, a suitable grounding adapter should
be used and the third wire should be grounded proper-
ly. To prevent risk of shock or fire hazard, always make
sure that the amplifier and all associated equipment is
properly grounded.
NOtE: FOr uK ONLY
As the colors of the wires in the mains lead of this appa-
ratus may not correspond directly with the colored mark-
ings identifying the terminals in your plug, proceed as
follows: (1) The green and yellow wire must be connected
to the terminal which is marked with the letter E, or by
the earth symbol, or is colored green, or green and yel-
low. (2) The blue wire must be connected to the terminal
which is marked with the letter N, or the color black. (3)
The brown wire must be connected to the terminal which
is marked with the letter L, or the color red.
VOLtaGE SELECtOr SWItCH
35
This switch allows the user to select between 115VAC /
60Hz or 230VAC / 50Hz. To change the voltage selector,
you must first unscrew and remove the plastic cover that
protects the switch. After changing the voltage, please
replace the plastic cover to ensure the voltage level is
not inadvertently altered.
NOtE: the fuse MuSt be changed to the appropriate
value to match the voltage you have selected. Please see
the note on the back of the mixer for the correct value.
MaIN / MONItOr SPEaKEr OutPutS
36
These are two-conductor 1/4" speaker outputs. Each
37
one is rated at 4 ohms minimum impedance. You may
connect either one 4-ohm, one 8-ohm or two 8-ohm
speakers to each output. Do not operate below rated
minimum impedance. For maximum power transfer, be
sure to use speaker cables and not instrument cables
to connect to the speakers. We recommend the use of
18-gauge or larger speaker wire.