EN
14
Problem
The product makes
a loud noise during
operation.
Water on floor
Error code
AS
ES
P2
Specifications
B07XHQQ95Y
Rated voltage:
Rated current:
Power input:
Standby power:
Moisture removal:
R.H. range:
Rated IEF:
Water tank capacity:
Refrigerant:
Fan IP rating:
Power cord and plug:
Air flow:
Sound emission:
Cause / Solution
•
The air filter is clogged.
•
The product is tilted instead of staying upright
as it should be.
•
The floor surface is not leveled.
•
The drain hose connection may be loose.
•
The drain hose outlet (P) might be opened.
Cause / Solution
•
Humidity sensor error.
•
Bring the product to a repair service.
•
Temperature sensor error.
•
Bring the product to a repair service.
•
Water container is full.
•
Empty the bucket.
•
Water container is not placed properly.
•
Rearrange the water container until it fits
properly in the housing.
115 V~, 60 Hz, single phase
max. 7.8 A
max. 810 W
1 W
50 pints/day (23.66 L/day)
35 – 85 % R.H.
0.48 gal/kWh (1.8 L/kWh)
1.59 gal (6 L)
R410A, 7.4 oz (210 g)
IP04
3- wire; grounded
11301/13066 cft/h (320/370 m
≤54 dB(A)
/h)
3