ENGLISH
6 Configuring via WIFI
SMARTSHUNT has integrated WIFI hot spot to which
you can connect with smart phone or any other device
that allows web browsing. It can be automatically
connected with scanning QR code bellow serial
number. You may get a message from the system, that
there may not be available internet connection but just
simply
run
your
web
config.lxnav.com. With pressing enter, configuration
page will show up. Before changing any parameter,
user should put SMARTSHUNT in config mode. That
means violet status LED must be lit. In any other mode,
settings will not be saved. For enabling WIFI or putting
it in config mode press Config button for more than a
second.
Configuration webpage that will show up consist of
four pages easily selectable on top of the screen:
Home, Battery config, Shunt config and Info page.
6.1.1
Homepage
On home page user can view all current data of system
in real time that are result of selected values on config
pages, for example voltages, temperatures, current
drawn, state of charge etc. as well as peak recorded
values and history of alarm messages.
6.1.2
Battery configuration
On this page user configures battery type with all
necessary data that are mandatory for correct
calculations of battery state and health.
Please do not access to the browser via QR
code for configuration, because browser does
not support popup windows and saving
configuration will not be possible.
The only way is to open browser and visit
config.lxnav.com. Then you can change and save
configuration settings.
browser
and
type
Page 13 of 112
6.1.3
Shunt configuration page
All
the
necessary
measurements should be filled out in this page. There
is also button setting for desired WIFI action.
6.1.4
Info page
On this page are all information about device. Its serial
number, hardware and software version.
in
6.2
Configuration via LXNAV Exxx device
Second option for configuration of SMARTSHUNT is via
any Exxx device. Assuming that the NMEA2000
network is established battery and shunt configuration
pages are accessible under different paths under
setting menus. In following two chapters are written
paths where menus can be found and their window
previews. For operating and calibrating external
devices on Exxx units refer also to Exxx user manual.
6.2.1
Battery setup
Parameters related to battery packs should be set in
menu that is accessible under this path:
Settings->Network->Device calibration->Battery
6.2.2
Shunt setup
Second configuration menu is found under:
Settings->Network->Connected devices->
Device details->Device setup
Parameters there relates to measurements between
shunt's terminals. There is also information about WiFi
hotspot
name
and
SMARTSHUNT accessible.
Inside shunt setup is submenu Alerts configuration
with user selectable parameters limits for warning
messages. There are seven warnings available in total.
7 First operation
SmartShunt will start to operate normally and indicate
real values after initial cycle. Initial cycle is finished,
when first time are fulfilled conditions for battery full
(Voltage must be higher than voltage setting for full
and charge current must drop below full current
setting)
To get really good performance, smart shunt will need
more charge/discharge cycles, to tune also other
parameters like charge efficiency....
data
related
to
current
password
under
which
is