LXNAV SmartShunt Manual De Instalación página 12

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ENGLISH
Shunt
parameter
Dependency between battery
capacity and discharge rate.
Peukert
Valid values 1.0 ~ 1.5 Initial
exponent
value is set automatically based
on battery chemistry.
Charger's efficiency. Valid
Charging
values 0.6 ~ 1.0 Value is
efficiency
constantly modified during
battery lifetime.
Dependency between battery
capacity and environment
Temperature
temperature. Valid values 0.0
coefficient
~ 1.0
Charger's float voltage. Initial
Voltage at
value is set automatically
battery full (V)
based on battery chemistry
and nominal voltage.
Charger's float current. Initial
Current
at
value is set automatically
battery full (A)
based on battery chemistry
and rated capacity.
Battery empty voltage. Initial
Voltage at
value is set automatically
battery empty
based on battery chemistry
(V)
and nominal voltage.
No action: WiFi is always on
and ready for configuration;
WiFi power: button press
enables or disables WiFi.
Config button
When enabled, it gets
action
automatically in config mode;
WiFi config: WiFi is enabled all
the time, with pressing button
SMARTSHUNT enters, or exit,
config mode;
SoC low limit
0, 5, 10, 15, 20, 25, 30, 35,
(%)
40, 45, 50, 55, 60
Table 5: Shunt parameters
Options
Page 12 of 112
Alert parameters:
Parameter values in this menu can be freely selected
by the user. When measurements are outside limited
values, warning message will be sent to NMEA2000
network and shown on screen of Exxx device. List of
available alerts is written bellow:
Alert parameter
Low voltage
High voltage
High charge current
High discharge
current
Low temperature
High temperature
Low state of charge
Table 7: Alarm parameter
Press ''SAVE'' to keep your settings.
Options
Alert will show up when
voltage on battery will be
bellow selected value
Alert will show up when
voltage on battery will be
above selected value
Set the maximum
charging current
Set upper limit of current
that can be drawn by
devices
Set low temperature limit
for alert
Set high temperature limit
for alert
Set when to alert battery
remaining capacity
loading