Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not use the product if signs of damage are found or if parts malfunction. Immediately have the product
repaired by Hilti Service.
After cleaning and maintenance, install all guards and protective devices and check that they are in full
working order.
To help ensure safe and reliable operation, use only genuine Hilti spare parts, consumables and
accessories. Spare parts, consumables and accessories approved by Hilti for use with your product
can be found at your Hilti Store or online at: www.hilti.group
9.1
Changing rubber feet
The rubber feet of the tower light are available as spare parts.
1. Unscrew the securing screws from the rubber feet and remove the faulty rubber feet.
2. Position the new rubber feet on the tower light and secure the rubber feet to the tower light with the
securing screws.
▶ Tighten the securing screws hand-tight.
9.2
Replacing cover of lamp head
The cover of the lamp head is available as a spare part.
1. Unscrew all outside securing screws from the lamp head and remove the faulty cover.
2. Position the new cover on the lamp head. Make sure that the holes in the cover and the holes in the lamp
head are in alignment. Make sure that the seal is correctly seated.
Materials
Cover, lamp head
SL 10­22­H
3. Screw the securing screws back into the lamp head.
▶ Tighten the screws hand-tight in diagonally opposite sequence.
10
Transport and storage
Transport of cordless power tools and batteries
CAUTION
Accidental starting during transport !
▶ Always transport your products with the batteries removed!
▶ Remove the battery/batteries.
▶ Never transport batteries loose and unprotected. During transport, batteries should be protected from
excessive shock and vibration and isolated from any conductive materials or other batteries that may
come in contact with the terminals and cause a short circuit. Comply with the locally applicable
regulations for transporting batteries.
▶ Do not send batteries through the mail. Consult your shipper for instructions on how to ship undamaged