5 Remove the battery from the Nailer.
6 Choose a suitable position for adjuster.
3. Using the hook (See Fig. 21, 22, 23)
WARNING
When using the hook, turn off the power switch (green
light "OFF"). Pay suffi cient attention so that the main
equipment does not fall.
If the tool falls, there is a risk of accident.
Hook can be installed on the left or right side.
1 Remove the battery, then remove all remaining nails
from the magazine.
2 Securely hold the main unit and remove the screw using
a screwdriver. (See Fig. 21)
3 Remove the hook and hook plate. (See Fig. 22)
4 Install the hook on the other side and securely fasten
with screw. (See Fig. 23)
NOTE
Hook can be used as a hanger.
4. Using the nose cap (See Fig. 24, 25)
WARNING
When attaching or detaching the nose cap, be sure
to remove your fi nger from the trigger and remove all
remaining fasteners and the battery from the nailer.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1 Remove all remaining fasteners and battery from nailer.
2 Put the nose cap to the toe of the push lever.
3 The nose cap is marked to indicate the exit point of the
nail, making alignment easier.
4 When not using the nose cap, secure in the storage
compartment located on the reverse side of the
magazine.
NOTE
The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
5. Clearing a jam
If nails are jammed in fi ring head, remove it, and adjust
the nailing in the following order.
CAUTION
Remove the battery from the Nailer.
1 Remove the battery from the Nailer.
2 Remove all nails.
3 Release the Lock lever and open guide plate. (See Fig.
26)
4 Remove the jammed nail with a slotted-head screwdriver.
(See Fig. 27)
CAUTION
○ NEVER hit the driver blade.
○ NEVER point the tool at yourself or another person, to
avoid risk of injury by mis-fi ring.
Even if the battery is removed from the nailer, there is still
energy of compressed air remaining inside.
5 Close guide plate and latch.
NOTE
In case of frequent jam, contact a HiKOKI authorized
service center.

MAINTENANCE AND INSPECTION

CAUTION
Be sure to remove all remaining fasteners and battery
from the nailer before maintenance and inspection.
1. Inspecting the magazine
1 Remove battery from the Nailer.
2 Clean the magazine. Remove dust and wooden
chips which may have accumulated in the magazine.
CAUTION
Check that the nail feeder slides smoothly by pulling it
with fi nger.
If not smooth, nails can be driven at an irregular angle
and hurt someone.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very "heart" of the power
tool. Exercise due care to ensure the winding does not
become damaged and/or wet with oil or water.
4. Cleaning on the outside
When the power tool is stained, wipe with a soft dry cloth
or a cloth moistened with soapy water. Do not use chloric
solvents, gasoline or paint thinner, for they melt plastics.
5. Storage
Store the power tool in a place in which the temperature
is less than 40°C and out of reach of children.
NOTE
Storing lithium-ion batteries.
Make sure the lithium-ion batteries have been fully
charged before storing them.
Prolonged storage (3 months or more) of batteries with
a low charge may result in performance deterioration,
signifi cantly reducing battery usage time or rendering
the batteries incapable of holding a charge.
However, signifi cantly reduced battery usage time may
be recovered by repeatedly charging and using the
batteries two to fi ve times.
If the battery usage time is extremely short despite
repeated charging and use, consider the batteries dead
and purchase new batteries.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
Important notice on the batteries for the HiKOKI
cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used with
batteries other than these designated by us, or when
the battery is disassembled and modifi ed (such as
disassembly and replacement of cells or other internal
parts).
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.