Technical Data; Power Requirements - Truper BOS-1/2LPX Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Technical data

Description
Voltage and Frequency
Current
Flow Rate
Maximum Depth
Maximum Height / Maximum
Manometric Height Value
Power Cable
Allows Particles Up To
Duty cycle
Conductors
Insulating
WARNING
make it replaced by the manufacturer or in a
Power insulation in this tool is affected by liquid spills or splashing while operating.
Do not expose to rain, liquids and / or humidity.
WARNING

Power Requirements

WARNING
The tool shall be grounded while in use to prevent an electric shock.
• Connect the plug into a correctly grounded power outlet, as shown in Figure A.
Not all the power outlets are correctly grounded. If you do not know for sure
verify with a qualified electrician.
• If the plug destined for the tool is a two-prong (two orifices), FOR NOT
REASON AT ALL REMOVE OR ALTER THE GROUND CONDUCTOR SET IN THE
PLUG. Use a temporary adapter as shown in Figure B and always connect the
ground ring as indicated.
When using an extension cable, verify the gauge is enough for
CAUTION
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows
the right size to use depending on cable's length and the ampere capability
shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
labeled "For Outdoors Use". These extensions are especially designed for operating outdoors and reduce
the risk of electric shock.
WARNING
All wiring, electrical connections and system grounding must comply with
MEXICAN OFFICIAL NOM-001-SEDE-2012, ELECTRICAL INSTALLATIONS or any local codes and
ordinances. You must use a qualified electrician.
BOS-1/2LPX
Code
15001
5,7 A
Power
1/2 Hp
Speed
1,537.4 gal/h
59'
50 minutes work per 20 minutes idle. Maximum 6 hours per day.
To prevent power discharge or serious accident if the power cable gets damaged
Before gaining access to terminals, all power circuits should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
BOS-3/4LPX
15002
Submersible Pump for Clean Water
127 V
8,5 A
3/4 Hp
3 450 RPM
1,711.8 gal/h
16,4'
85'
30'
0,13"
18 AWG x 3 C with insulating temperature of 221 °F
Class I
Power cord grips used in this product: Type "Y".
Build quality: Basic insulation
Thermal insulation on motor winding: Class E
Authorized Service Center.
Extension gauge
from 6 ft to 49 ft
18 AWG( * )
16 AWG
14 AWG
8 AWG
BOS-1LPX
15003
60 Hz
10,5 A
1 Hp
1,854.4 gal/h
108'
WARNING
|
higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
grounded extension cable
ENGLISH
A
B
3

Hide quick links:

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Bos-3/4lpxBos-1lpx150011500215003