Kohler K-19796 Manual De Instrucciones página 6

Ocultar thumbs Ver también para K-19796:
Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide (cont.)
Symptoms
Recommended Action
2.
The fill
A. Clean the seal located on the flush valve or
valve turns
replace the flush valve if the seal is damaged.
on/off by
itself
without the
toilet being
flushed, or
it runs,
allowing
water to
enter the
tank.
B. Remove the tank from the bowl, then tighten the
nut on the flush valve if the gasket on the flush
valve is leaking. Do not overtighten. If leakage
continues, replace the flush valve.
C. Replace the fill valve if the float on the fill valve
sinks.
D. Adjust the tank water level if the water level is
too high.
3.
Long tank
A. Fully open the water supply shut-off valve.
fill cycle.
B. Clean the valve inlet, head of the fill valve, or
supply line. Flush the lines.
4.
Noisy tank
A. Partially close the water supply stop valve located
fill cycle.
inside the tank if the water pressure to the toilet is
too high. Check the toilet performance following
any such adjustment.
B. Remove dirt or obstructions from the head of the
fill valve. Flush the lines.
1052867-5-B
6
Kohler Co.
loading