RIB DUKE B2D 24V-CRX Manual De Instalación página 41

Idiomas disponibles
  • ES

Idiomas disponibles

EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety
device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian
opening
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and
R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Intervention of impact sensor
Failure of a safety device or safety device engaged for too long
Running with emergency batteries (24 vdc)
Emergency batteries low signal
Operation with emergency batteries charged by solar panels
Alarm from edge
Impact sensor alarm
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9
and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace any faulty components.
DL6
OFF
Stop button malfunction (if Stop is not connected, perform the jump between COM A+ and STOP).
DL7 or DL8
OFF
Faulty photocells (In case the edge is not connected, carry out jumper between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10
OFF
Faulty safety edge (In case the edge is not connected, carry out jumper between COM A+ and EDGE 1/EDGE 2)
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1 and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the
red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
LED DL13 (BLUE)
ON
Some functions are enabled via smartphone, so via smartphone check the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit, interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and insert them one at a time in order to more easily identify the cause of the fault.
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
Off
Off
Off
10 seconds tone with 2 seconds pause
BUZZER STATUS
Off
Off
Off
Off
1 Tone
1 Tone
Off
Off
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
Off
1 Tone
2 Tones
3 Tones
Off
Off
1 Tone every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
3 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
6 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
41
FLASHER STATUS
Off
Flashes on-off 250 ms
Off
Flashes on-off 500 ms
Off
Flashes on-off 500 ms
Off
On steady
FLASHER STATUS
Off
Flashes intermittently red/green
Off
Flashes red for 10 seconds
Off
Flashes green for 10 seconds
Off
Flashes orange for 10 seconds
Off
Turns green once
Off
Turns red once
Off
Red flash
Off
Runs 6 green flashes
Off
Runs 2 green flashes
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Off
Led DL6 turns off
Off
Led DL7-8 turns off
Off
Led DL9-10 turns off
Off
No led combined
Off
Led DL1 flashes on-off 250 ms
Currently enabled
Signal output flashes on-off twice for 250 ms
followed by a pause of 2 seconds
Off
Signal output flashes continuously on-off for 500
ms
Off
Signal output flashes on-off 3 times for 250 ms
followed by a pause of 2 seconds
Enabled for 1 minute
No led combined
Enabled for 1 minute
No led combined
Off
No led combined
Off
Led DL12 is steady on green.
Off
No leds matched
Off
Blue led flashes once every 5 seconds
DL1 LED STATUS
DL12 LED STATUS
G
B
loading

Este manual también es adecuado para:

Abb2060Abb2061Ac08072