Chapter 4 Menu and operation
【SET】
▼
Process cond:
Stand Liquid
【SET】
▼
Range:
LRU: 00.000 m
URU: 05.000 m
【SET】
▼
Alarm1: None
ON:
00.000 m
OFF:
00.000 m
- 26 -
medium are liquid and solid.
According to the measured working
conditions, the corresponding process
conditions are selected, and the system will
select different algorithms and working
modes according to the unable working
conditions to make the system run in the
best state. Process conditions include
standard liquid, calm liquid level, disturbed
liquid level, stirrer, rapid change, standard
solid, solid dust, conveyor belt and test
options. Standard liquid and standard solid
are selected by default. The test option is
used for field debugging and there is no
algorithm for various working conditions.
The current output range is set, with the low
position corresponding to the value of 4mA
current and the high position corresponding
to the value of 20mA current.
There are three alarm modes, high alarm,
low alarm and no alarm. When high alarm
is selected, when it is greater than the
power-on alarm value, the power supply
alarm output is turned on, and when it is
less than the power-off alarm value, the
power supply alarm is turned off. When low
alarm is selected and is less than the power-