Volpi Kamikaze PV295 Manual Del Usuario página 43

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
P. Press the plastic cap.
R. Screw the M5 socket screw as shown.
Screw the M5 hexagon socket countersunk
M.
head counterclockwise as shown.
15.4. Tool Calibration
If a replacement motor or drive plate is required, the pruners need to be recalibrated.
Follow next steps to perform the calibration:
1) Remove the upper and lower blades.
2) Insert the battery.
P
Q. Insert the ring nut.
R
S. Place the flat needle roller bearing and the
washer as shown and screw on the locking nut.
T
N. Reduce the friction between the two plans of
the blades by adding grease through the hole of
the plastic cap as shown in the figure.
Q
S
U
43