Campbell Hausfeld FP2003 Instrucciones Para La Operación
Campbell Hausfeld FP2003 Instrucciones Para La Operación

Campbell Hausfeld FP2003 Instrucciones Para La Operación

Compresores sin aceite

Enlaces rápidos

Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
!
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
© 1999 Campbell Hausfeld
Oilless
Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
A listing of service center locations is
enclosed. Have the serial number,
model number, and parts list (with
missing parts circled before calling.)
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
Since the air compressor and other
General Safety
Information
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
For parts, product & service information
visit www.campbellhausfeld.com
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).
IN224001AV 5/99
FP2003
Need
Assistance?
Call Us First!
1-800-543-8622
MANUAL
loading

Resumen de contenidos para Campbell Hausfeld FP2003

  • Página 1 Hausfeld Authorized Service Center. serious injury. warranties shall be voided, and A listing of service center locations is Campbell Hausfeld disclaims any Caution indicates a enclosed. Have the serial number, potentially liability whatsoever for any loss, model number, and parts list (with hazardous situation which, if not personal injury or damage.
  • Página 2 Oilless Compressors General Safety Installation Information (Continued) Never attempt to repair LOCATION or modify a tank! 3. Only persons well acquainted with It is extremely important to use the Welding, drilling or any these rules of safe operation should compressor in a clean, well ventilated other modification will weaken the be allowed to use the compressor.
  • Página 3 FP2003 Installation (Con’t) Handle ON/OFF Switch Improper use of grounding plug can result in a possible risk of Regulator electrical shock! Do not use a grounding adapter with this product! 2. If repair or replacement of cord or plug is necessary, do not connect grounding Safety Valve wire to either flat blade terminal.
  • Página 4 Oilless Compressors Operation (Continued) MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air ASME SAFETY VALVE compressor pump. When humidity is high or when a compressor is in continuous Do not remove or use for an extended period of time, this moisture will collect in the tank.
  • Página 5 FP2003 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No power or switch in OFF position 1. Make sure compressor is plugged in and switch is ON 2. Blown fuse (usually indicated by no 2. Disconnect compressor from power source then light in power switch) remove pump shroud.
  • Página 6 Oilless Compressors Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Compressor runs 1. Excessive air usage, compressor too 1. Decrease usage or purchase unit with higher air continuously and air small delivery (SCFM) output is lower than 2. Air leaks in piping (on machine or in 2.
  • Página 7 FP2003 For Replacement Parts, Call 1-800-543-6400 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: The Campbell Group Attn: Parts Department 100 Production Drive Harrison, OH 45030 U.S.A.
  • Página 8 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Página 9 Puisque le compresseur d’air et les autres Codes (NEC) and Occupational Safety boulon, etc., avant de mettre ce produit pièces détachées (pompe, pistolets, filtres, en service. En cas de dommage ou de and Health Act (OSHA) des É-U. IN224001AV 5/99 © 1999 Campbell Hausfeld 9 Fr...
  • Página 10 Compresseur Sans Huile Généralités Sur La Tenir la soupape de sûreté libre de Installation peinture et d’autres accumulations. Sécurité (Suite) ENDROIT DANGER 3. Seules les personnes bien familiarisées Il est très important d’utiliser le Ne jamais essayer de réparer avec ces règles d’utilisation doivent compresseur dans un endroit propre et ou de modifier un réservoir! être autorisées à...
  • Página 11 FP2003 déclenchement du protecteur de Installation RODAGE (Suite) courant à maintes reprises, il peut être Ne pas ATTENTION brancher nécessaire de faire fonctionner le DANGER les outils pneumatiques au bout du compresseur sur un circuit de 120 volts, tuyau jusqu’à ce que le démarrage soit L’usage incorrect d’une fiche...
  • Página 12 Compresseur Sans Huile Fonctionnement (Suite) L’HUMIDITÉ DANS L’AIR COMPRIMÉ 7. Fixer un mandrin ou autre outil au L’humidité dans l’air comprimé forme des goutelettes en arrivant de la pompe bout ouvert du tuyau. Tourner le du compresseur. Si l’humidité est élevée ou si le compresseur est utilisé régulateur On.
  • Página 13 FP2003 Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne 1. Manque d’alimentation ou 1. S’assurer que le compresseur soit branché et que fonctionne pas interrupteur dans la position hors l’interrupteur soit ON (en marche) circuit (OFF) 2. Fusible sauté (souvant indiquée par 2.
  • Página 14 Compresseur Sans Huile Guide De Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesures Correctives Perte de pression quand 1. Robinet de vidange desserré 1. Serrer le compresseur s’arrête 2. Fuite de clapet 2. Démonter le montage de clapet, nettoyer ou remplacer 3. Connexions desserrées au manostat 3.
  • Página 15 FP2003 Pour Pièces De Rechange, appeler 1-800-543-6400 S’il vous plaît fournir l’information suivant: Correspondance concernant les pièces : -Numéro du modèle The Campbell Group -Numéro de série (si applicable) Attn: Parts Department -Description de la pièce et son numéro sur la liste de pièces 100 Production Drive Harrison, OH 45030 U.S.A.
  • Página 16 8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Página 17 No. de Serie ______________________ PELIGRO de seguridad y alarma, todas la garantías se indica que anularán y la compañia Campbell Hausfeld hay una situación inmediata que LE Fecha de Compra ____________________ no asumirá NINGUNA responsabilidad por OCASIONARIA la muerte o heridas de Guarde estos números para...
  • Página 18 Compresores Sin Aceite más lejos posible del área de trabajo, determinar la razón. Generalmente, la Informaciones para minimizar la acumulación de vibración excesiva se debe a una falla. Generales de Seguridad residuos en el compresor. 11. Para reducir el peligro de incendio, (Continuacíon) 18.
  • Página 19 FP2003 c. Los cordones de extensión son los drenar la humedad del tanque diaria- Instalación adecuados y cumplen los requisitos mente, para evitar que el tanque se (Continuacíon) mínimos especificados en este oxide. manual de instrucciones. Reduzca la presión del tanque a menos Terminal d.
  • Página 20 Compresores Sin Aceite Funcionamiento HUMEDAD EN EL AIRE COMPRIMIDO (Continuacíon) La humedad que se acumula en el aire comprimido se convierte en gotas a medida que sale del cabezal del compresor de aire. Cuando el nivel de humnedad es muy alto o apagará...
  • Página 21 FP2003 Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción a tomar El compresor no 1. No hay corriente eléctrica, o el 1. Cerciórese de que el compresor esté conectado al funciona interruptor está en OFF (apagado) tomacorriente y el interruptor esté en ON (encendido) 2.
  • Página 22 Compresores Sin Aceite Guía de diagnóstico de averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar La presión del tanque 1. Llave de drenaje floja 1. Ajuste cae cuando se apaga el 2. Válvula de retención con fugas 2. Re el cabezal compresor 3.
  • Página 23 FP2003 Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio Sírvase darnos la siguiente información: Puede escribirnos a: -Número del modelo The Campbell Group / Attn: Parts Department -Número de Serie (de haberlo) 100 Production Drive -Descripción y número del repuesto según la lista de repuestos Harrison, OH 45030 U.S.A.
  • Página 24 A. La reparación o reemplazo dependerá del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos. B. Si el comprador no recibe resultados satisfactorios en el Centro de Servicio a Clientes de Campbell Hausfeld. (Vea el Párrafo 2).