Atmor Thermo Pro2 Serie Manual De Instrucciones página 11

Idiomas disponibles

Idiomas disponibles

Electrical Specifications by Heater Input
Item #
kW
AT-912-36TP2
36
Power Rates
Item #
240V
AT-912-36TP2
36,000 Watts
Wiring Diagram for 36kW
40 Amp
Double Pole
L1
Your tankless water heater is now installed and ready to use! Follow the General Operating Instructions to complete
the setup.
Max
Required Breaker
Amps
150
4 x 40A Double Pole
220V
30,250 Watts
40 Amp
40 Amp
Double Pole
Double Pole
Double Pole
L2
L1
L2
L1
L2
L1
Unit Requires 10 AWG ground wire - one for each 240V circuit
Req. Wire Size
4 x 8/2 AWG with Ground
208V
27,040 Watts
40 Amp
L1 L2
L1 L2
L2
8/2 AWG
8/2 AWG
8/2 AWG
8/2 AWG
Terminal Block in Unit
L1 L2
L1 L2
11