Measuring DC Voltage
(See Figure 2)
1. Set the Function Switch to
.
2. Select the desired RANGE. The default AC voltage
range is 2 V on the 15XP-B and 4 V on the 35XP-A.
3. Connect the test leads: Red to V , Black to COM.
4. Connect the test probes to the circuit test points.
5. Read the display, and, if necessary, correct any
overload (
) conditions.
0o
Preparing for Current Measurements
• Turn off circuit power before connecting the test probes.
• Allow the meter to cool between measurements, if current
measurements approach or exceeds 2 amps.
• A warning tone sounds if you connect a test lead to a
current input while a current function is not selected.
• Open circuit voltage at the measurement point must not
exceed 600V.
• Always measure current in series with the load. Never
measure current across a voltage source.
Measuring DC Current
(See Figure 3)
1. Set the Function Switch to a current function, μA, mA,
or A.
2. Select the desired RANGE (5XP-A only).
3. Connect the test leads: Red to mA or A, Black to COM.
4. Turn off power to the circuit being measured.
5. Open the test circuit (
X
) to establish
measurement points.
6. Connect the test probes in series with the load (to the
measurement points).
7. Turn on power to the circuit being measured.
8. Read the display, and, if necessary, correct any
overload (
0o
or
-0o
) conditions.