Futurelight CY-250 Manual Del Usuario página 25

Idiomas disponibles

Idiomas disponibles

Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the CY-250 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the CY-250 can be used without controller. You can do without a controller as the
CY-250 features a built-in microphone, which provides automatic sound control.
Disconnect the CY-250 from the controller and select "Master Mode: Sound-control".
If you have connected a footswitch to the Blackout-socket, you can lock the light output (Blackout-mode) and
turn it on again.
Master/Slave-operation
Connect the master and slave-devices and adjust the settings as desribed above.
Please note: If you wish to change from one operating mode into another, you have to unplug the projector
from the mains and plug it again.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. In order to call up the different features, you first have to open the shutter
(control channel 6, DMX-value 132-139 or 250-255) or set the dimmer to the desired intensity (control
channel 6, DMX-value 6-128).
Addressing
The Control Board on the front side of the base allows you to assign the DMX fixture address, which is
defined as the first channel from which the CY-250 will respond to the controller.
If you set, for example, the address to channel 7, the CY-250 will use the channel 7 to 14 for control.
Please, be sure that you don't have any overlapping channels in order to control each CY-250 correctly and
independently from any other fixture on the DMX data link.
If two, three or more CY-250 are addressed similarly, they will work similarly.
For address setting, press the Mode-button until the display shows "d" and set the desired address via the
Up/Down-buttons.
Controlling:
After having addressed all CY-250, you may now start operating these via your lighting controller.
All manuals and user guides at all-guides.com
25/52
51837530X18NXS_V_1_0.DOC