Lamp adjustment
the light is bright and evenly distributed.
Overhead rigging
Please consider the DIN 15560 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Machine-technical installations in the sense of these instructions are all technical installations and working
material used for operating places of events and productions for scenery presentations.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and or
damage to property.
All manuals and user guides at all-guides.com
The lampholder is aligned at the factory. Due to
differences between lamps, fine adjustment may
improve light performance.
Strike the lamp, open the shutter, set the dimmer
intensity onto 100 % and focus the light on a flat
surface (wall). Center the hot-spot (the brightest part
of the beam) using the 3 adjustment screws "A, B,
C". Turn one screw at a time to drag the hot-spot
diagonally across the projected image. If you cannot
detect a hot-spot, adjust the lamp until the light is
even.
To reduce a hot-spot, pull the lamp in by turning all
three screws "A, B, C" clockwise ¼-turn at a time
until the light is evenly distributed.
If the light is brighter around the edge than it is in the
center, or if light output is low, the lamp is too far back
in the reflector. "Push" the lamp out by turning the
screws "A, B, C" counterclockwise ¼-turn at a time
DANGER TO LIFE!
22/52
51837530X18NXS_V_1_0.DOC