Daikin CTX07AXVJU Manual De Instalación página 8

Ocultar thumbs Ver también para CTX07AXVJU:
Idiomas disponibles

Idiomas disponibles

A Mounting plate
D Wireless remote controller
G Drain socket
• Before choosing the installation site, obtain user approval.
Indoor Unit
The indoor unit should be sited in a place where:
• The restrictions on installation specified in the indoor
unit installation drawing are met.
• Both air intake and exhaust have clear paths met.
• The unit is not in the path of direct sunlight.
• The unit is away from the sources of heat or steam.
• There is no source of machine oil vapor (this may
shorten indoor unit life).
• Cool air is circulated throughout the room.
• The unit is away from electronic ignition type
fluorescent lamps (inverter or rapid start type). As these
may shorten the remote controller range.
• The unit is at least 3.5 ft away from any television or
radio set (unit may cause interference with the picture
or sound).
• Do not install the units at or near doorway.
• Do not operate any heating apparatus too close to the
air conditioner unit or use in room where mineral oil,
oil vapour or oil steam exist, this may cause plastic
part to melt or deform as a result of excessive heat or
chemical reaction.
• When the unit is used in kitchen, keep flour away from
going into suction of the unit.
• This unit is not suitable for factory use where cutting oil,
mist or iron powder exist or voltage fluctuates greatly.
• Do not install the units at area like hot spring or oil
refinery plant where sulphide gas exists.
• Ensure the color of wires of the outdoor unit and the
terminal markings are same to the indoors respectively.
• IMPORTANT : DO NOT INSTALL OR USE THE AIR
CONDITIONER UNIT IN A LAUNDRY ROOM.
Do not use joined and twisted wires for incoming power
supply.
The equipment is not intended for use in a potentially
explosive atmosphere
Wireless Remote Controller
• Do not expose the remote controller to direct sunlight
(this will hinder receiving signals from the indoor unit).
• Turn on all the fluorescent lamps in the room,
if any, and find the site where remote controller signals
are properly received by the indoor unit (within 23ft
(7 metres)).
ACCESSORIES
1
B Remote controller holder
1
E Fixing screws for remote
controller holder M3 × 16L
1
H Drain plug
CHOOSING AN INSTALLATION SITE
1
C AAA dry-cell batteries
2
F Titanium apatite deodorizing
12
I Installation manual
J Operation manual
Outdoor Unit
The outdoor unit should be installed in a place where:
• The restrictions on installation specified in the outdoor
unit installation drawing are met.
• Condensate draining from the bottom of the unit causes
no trouble or problem in particular.
• Both air intake and exhaust have clear paths of air.
• The unit is in a clear path of air but not directly exposed
to rain, strong winds, or direct sunlight.
• There is no fear of inflammable gas leakage.
• The unit is no directly exposed to salt, sulfidized gases, or
machine oil vapour (they may shorten outdoor unit life).
• Operation noise or hot (cold) air flow does not cause
trouble to neighbours.
• The unit is at least 10ft (3 metres) away from any
television or radio antenna.
• Condensation dripping from the stop valve cannot
damage anything during operation.
CAUTION
When operating the air conditioner in a low outdoor
ambient temperature, be sure to follow the instructions
described below.
• To prevent exposure to wind, install the outdoor unit
with its suction side facing the wall.
• Never install the outdoor unit at a site where the suction
side may be exposed directly to wind.
• To prevent exposure to wind, it is recommended to install a
baffle plate on the air discharge side of the outdoor unit.
In heavy snow areas,
select an installation site
where the snow will not
affect the unit.
• If there is a likelihood of
snow accumulating on the
outdoor unit, attach a snow
protection hood.
• In high humidity areas or
heavy snow areas, it is
recommended to attach a
drain pan heater to prevent
ice build-up from the bottom
frame.
1-6
filter
• Construct a large canopy.
• Construct a pedestal.
Install the unit high
enough off the ground to
prevent burying in snow
2
2
1
1
loading

Este manual también es adecuado para:

Ctx09axvjuCtx12axvju2mx18axvju