Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with 5
suitable screws for FTXN/FTK 25/35 and 7 suitable screws
for FTXN/FTK 50/60.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
FTXN 25/35
FTK 25/35
Mounting plate
fixing screw
FTXN 50/60
FTK 50/60
Mounting plate
fixing screw
Recommended Mounting Plate Retention Spots And
Dimensions
FTXN 25/35
FTK 25/35
« Recommended mounting plate retention spots
(5 spots in all)
104
153
52
55
207
800
Liquid pipe end
Gas pipe end
FTXN 50/60
FTK 50/60
« Recommended mounting plate retention spots
(7 spots in all)
190
Liquid pipe end
45
91
580
45
1065
Mounting plate
Mounting plate
141
Through the wall hole Ø 65mm
Drain hose position
181
56
All dimensions are in mm
173
Through the wall hole
Ø 65mm
Drain hose position
Gas pipe end
219
48
All dimensions are in mm
Hole with cone drill
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front
grille) to release the claws.
Front grille
Hang indoor unit's hook here.
When stripping the ends
of interconnecting wires in
advance, bind right ends of
wires with insulating tape.
Wire guide
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Water Drainage
Water
Water
leaking
leaking
Correct
Wrong
! CAUTION
• Do not install the unit at altitude over 2000m for both
indoor & outdoor.
1-9
Outside
Caulking
Ø 65
Wall embedded pipe
(Field supply)
Mounting plate
Clip
Bottom frame
Mark (Rear side)
Mounting plate
Interconnecting
wires
Water
retention
End
dipped
Water
into
leaking
water
Wrong
Wrong
Drain
loading