Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically cuts
off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the trigger switch on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
trigger switch again to restart.
If the tool does not start, the battery is
overheated. In this situation, let the battery
cool before pulling the trigger switch again.
Low battery voltage:
The remaining battery capacity is too low and
the tool will not operate. In this situation,
remove and recharge the battery.
Switch action
1
012524
Indication lamp
The lamp blinks in red.
The lamp lights up in red.
(Note 1)
The lamp lights up in red.
(Note 1)
Note 1: The time at which the indication lamp lights up varies by the temperature
around the work area and the battery cartridge conditions.
010970
1. Lock-off button
2
2. Switch trigger
This indicates the appropriate
time to replace the battery
cartridge when the battery
power becomes low.
This function works when the
battery power is almost used
up. At this time, tool stops
immediately.
Autostop due to overload.
CAUTION:
Before inserting the battery cartridge into the tool,
always check to see that the switch trigger
actuates properly and returns to the "OFF" position
when released.
To prevent the switch trigger from being accidentally
pulled, a lock-off button is provided.
To start the tool, depress the lock-off button and pull the
switch trigger. Release the switch trigger to stop. The
lock-off button can be pressed from either right or left
side.
Indication lamp
1
012523
Running the tool allows the indication lamp to show the
battery cartridge capacity status.
When the tool is also overloaded and has stopped
during operation, the lamp lights up in red.
Refer to the following table for the status and action to
be taken for the indication lamp.
Status
Recharge the battery cartridge
as soon as possible.
Recharge the battery cartridge.
Turn off the tool.
5
1. Indication lamp
Action to be taken
loading