EuroLite FS-600 CDM Spot Manual Del Usuario página 17

Idiomas disponibles

Idiomas disponibles

INSTALLATION
Installing/Replacing the lamp
For the installation, you need one CDM-T 150W/920 G12 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the knurled screw of the lamp housing.
Step 2: Remove the lamp housing from the device.
Step 3: If replacing the lamp, remove the old lamp from the socket.
Step 4: Insert the CDM-T 150W/920 G12 lamp into the lamp-socket.
Step 5: Replace the lamp housing onto the device and tighten the screw.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Lamp housing
Knurled bolt
CAUTION!
CDM-T Lamp
Lamp base
Lamp brackets
17/39
40002600_V_1_0.DOC
loading