1 - SEE THE TROUBLESHOOTING TABLES
NO HOT WATER
I - o be checked by the user:
- The knob is turned as far as possible to the right
- Check that one of the protection devices has not dropped (circuit-breaker)
or replace fuse
If the steps in point I are checked, and the problem is not resolved, proceed as follows:
II - Take care, check at every stage that the device is turned off, using a
voltage checker..
- Turn off power and check that it is off on the appliance's mains connection
to the building power.
- Open the cover underneath the appliance (vertical position) or on the
left (horizontal position) unscrewing the 4 screws with a cross-head
screwdriver.
- Check that the thermal cut-off (see diagram 3.1 page 93) has not
tripped by pressing the small round button in the centre.