ENGLISH
DESCRIPTION
Once connected to the iO Simon socket (ref.10002432-039), this front with WiFi and Z-Wave
antennas allows you to link via App Simon | 100 iO to a smart device (mobile or tablet) to register
an iO Simon connective installation. Allows the high and remote control of any iO Simon device
and other compatible Z-Wave devices that are within the same installation.
In addition, it allows the control ON / OFF of a load plugged in via local or wireless pulse and has
extended functions (timing, calendar, power limitation, etc.) configurable from the App.
KEYPAD USE & FEEDBACKS
EVENT
KEYPAD
LOAD
FEEDBACK LEDS
ACTION
STATE
Not linked to APP
Simon100 iO or to a
- LED1 blinks slow in blue.
Z-Wave network.
- OFF due to load limit
consumption
blinking)
- OFF with no load limit con-
sumption (LED1 white)
Not pressed
- ON with load limit
Linked to APP
consumption (LED1 orange)
Simon 100 iO or to
a Z-Wave network.
- ON with no load limit
consumption (LED1 green)
- Beacon, LEDs 1...7 set their
intensity according Param 3.
- Error, Fast blink in Central LED.
OFF
LED1 turns green or orange
Press key
Short press
(t<2sec)
ON
LED1 turns white
Is the main controller
(sis) of the network.
Add/
Remove
Long press
There are no devices
added into HUB iO
to/from
(2s <t <10s)
network
Z-Wave
or it is not the main
Network
controller (SIS) of
the Network
Linked
Long press
to app
LED1 blinks in blue.
(10s <t
Simon100
<20s)
IO
Reset
Long press
LED1 flashes blue fast.
Software
(20s <t
<30s)
Main LED light up for 2.5
Reset
Long press
sec. After that LED1 turns
default
t>30s
blue during the reset.
* If the LED of the button lights up or blinks in Blue, all other signals will not be displayed.
* If the stop button is not pressed, the push button LED will blink red 3 times at a frequency of 0.5s
* Some of the functions can be changed depending on the configuration parameters.
* This device can only be included or excluded in a Z-Wave network if you have not added any other
equipment to your own Z-Wave network.
Z-WAVE COMPLIANCE
This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other applications. All non-battery operated nodes
within the network will act as repeaters regardless of vendor to increase reliability of the
network.
This product is a Security Enabled Z-Wave Plus Controller that can manage both, secure and
unsecure Z-Wave devices
Z-WAVE SPECIFICATIONS
CONTROLLER COMMAND CLASSES
SUPPORTED COMMAND CLASSES
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_METER_V4
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_METER_V4 (Electric measurement;
Watts, Voltage and Current measurement allowed)
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_SECURITY_V1
CC BASIC SET VALUES MAPPING
Z-WAVE DEVICE SPECIFICATION
Device Type:
CENTRAL CONTROLLER
If Basic Set is received from
Generic Device Type:
GENERIC TYPE STATIC
a Simon "Master" device
selected as trigger of an
CONTROLLER
experience
Specific Device Type:
SPECIFIC TYPE PC
CONTROLLER
Other cases
Role Type:
ROLE TYPE CONTROLLER
CENTRAL STATIC
ID
Name
Max. Nodes
CommandClass
Asociadas
ID
Name
Max. Nodes
CommandClass
LOAD ACTION
Asociadas
(LED1
red
Load is deactivated if load
1
consumption limit is exceeded.
2
Load is deactivated if load
consumption (16A) is exceeded.
3
10
11
16
12
Load is activated
Load is deactivated
13
Device sends a Node Info.
Central LED blinks.
15
Device goes to learning mode to be
added on other Z-Wave network.
Central LED blinks. This action
17
can also be performed to redis-
cover. This action can also be
used to replicate other Z-Wave
19
Controller.
LED1 stays blue; LEDs 2..7 turn
20
ON or OFF showing an link code
to allow user manage the Z-Wave
Network through the Simon 100
21
iO 100 APP.
The link code finishes once user is
linked to HUB iO or after 3 minu-
tes without any user link.
27
Restart the WiFi interface
COMMAND_CLASS_DEVICE_RESET_LOCALLY -> DEVICE_RESET_LOCALLY_NOTIFICATION
Reset to default state.
will be sent to inform controller that node has been removed from network, but the device
will keep the current configurations.
To restore the configurations values, please perform one of these actions:
will set the 0xff value.
Experience is performed
Values are mapped as "Power
On/Off Switch", Activaing/
Deactivating the socket Relay
According the Basic Set Value
ASSOCIATION GROUPS
1 (Lifeline)
"Lifeline"
3
COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load changes state:
ON -> 0xFF
OFF -> 0x00
COMMAND_CLASS_METER_REPORT_V4
It is sent to the associated nodes when the power consumed varies more than 10%
"Electric meter", "Consumed", "Watts", Size 4, Precision 1, Value (W)
COMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATION
The associated nodes are sent when the device is deleted from the Z-Wave network
2 (Control)
"Ctrl"
20
COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load changes state:
ON -> 0xFF
OFF -> 0x00
CONFIGURATION
NAME
VALUE
SIZE
0x00 -> (Default) Turns off the center LED
Central LED
1
0xFF -> Turn on the center LED
0x0000 -> (Default) Disables custom consumption limit
Custom consumption limit
2
0x0001 - 0xFFFF -> Sets the power in Watts that is supported
(once the load is over, it is disabled).
0x00 -> (Default) Disables the beacon function
Beacon
1
0x01-0x63 (1-100%) -> Sets the intensity of the beacon LEDs.
On Timed
0x00 -> (Default) Disables timing
1
0x01-0x7F -> Sets a timing with a range of (1-127sec)
Off Timed
Delayed Off
0x80-0xFE -> Sets a timing with range of (1-127min)
0x00 -> The pushbutton LED reflects the status of the load only
for 5sec after a status change
1
LED at rest
0xFF -> (Default) The pushbutton LED reflects the status of the
load
0x00 -> (Default) Enables the pushbutton to control the load
Local lock
1
0xFF -> Disables the action of the pushbutton on the load
0x9867 -> Parameters, Groups and Z-Wave status are restored
to the default values.
Reset default (Write only)
2
0x4312 -> Parameters, with the exception of Long Pulse Lock, are
reset to default values.
0x00 -> After a reset the load starts off
1
PostReset State
0xFF -> (Default) After a reset the load starts activated
0x00 -> TOGGLE (Default). A short press (t <2s) switches the
load
Action when pressing
1
0x01 -> ON. A short press (t <2s) activates the load
0x02 -> OFF. A short press (t <2s) deactivates the load
0xFF -> The central LED flashes for 5 seconds at a frequency of
Identify (Write Only)
1
0.1s
[Byte 0]
0x00 -> Charging is disabled
0x01 -> Charging is activated
Charge status (Read only)
2
[Byte 1]
0x00 -> Charging is disabled
0xFF -> Charging is activated
0x00 -> (Default) The long press (t> 2s) works as described in the
usage and signaling table
Long key press
1
0xFF -> Pressing 2s <t <10s does not send Node Info
Pressing t> 30s resets the configuration parameters except
Long Hold Lock and sends a Node Info
All These configurations are not restored to default when device is removed from network.
- Use Command CONFIGURATION SET with default bit to 1 for each
configuration parameter.
- Perform Reset Default Action via keypad pressing or configuration command
default.
On parameters that only accepts 0x00 n 0xff values, any set value different than 0x00
SIMON, S.A.U. Diputación, 390-392 / 08013 Barcelona
www.simonelectric.com