There are different parameters that can be configured by portable programmer. Below is a description of the most basic. Refer to the
programmer instruction manual for further information.
Operation by Time: Indicates if the panel is programmed to operate by time.
-
Operation by Pulses: Indicates if the panel is programmed to operate by pulses.
-
Oper. counter limit: Indicates / selects the limit number of operations for the panel.
-
Operation counter: Indicates the number of operations made to date.
-
Autoclosing time: Indicates / selects the seconds of automatic standby time.
-
Equip.: Shows an equipment identifier.
-
Low speed starting open: Indicates / selects slow speed at start of opening operation.
-
Low speed starting clos.: Indicates / selects slow speed at start of closing operation.
-
Last 4cm inh. space: Indicates / selects the seconds or pulses equivalent to 4cm of distance for the disabling of the security
-
band.
Troubleshooting
The following table indicates the possible causes of operating failures in the control panel through the ERROR and SAFETY leds.
Description
Stop enabled
Security band enabled
Safety contact enabled
Excess consumption on closure
Excess consumption on opening
Panel programmed by times
Panel not referenced or waiting to start reference search
Security band not connected
Maximum current limit exceeded
End of run or programmed reference not reached
No encoder pulses
Panel programmed without references
Internal error
Receiver operating
Upon receiving a code, the equipment checks whether it is in its memory, activating the corresponding relay.
Manual programming
3) Normal programming
Press the RADIO PROG programming button for 1 sec. The programming RADIO PROG pilot light will come on and the equipment
will emit an acoustic signal. The equipment will enter normal programming. Send the code and the channel to be programmed by
pressing the transmitter.
By pressing the transmitter channel, opening and closure is activated in automatic operating mode.
4) Programming for pedestrian function
In normal programming, press the RADIO PROG programming button again and keep it pressed down until the RADIO PROG pilot
light flashes and the equipment emits a short acoustic signal. The equipment will now have entered programming for pedestrian
function. Press the required channel of the transmitter to be programmed.
Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without programming
or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic signals. If, on
programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit programming.
N.B.: Each transmitter channel can be configured independently on the equipment, occupying only one memory position.
Programming via radio
To enter programming, press the first two buttons on a transmitter that has already been registered on the equipment. The equipment
will issue a 1 sec. acoustic signal. On pressing any button on the new transmitter, the equipment will issue another 1 sec. acoustic
signal to indicate that it has been memorised. The new transmitter will maintain the same channel configuration as the transmitter
registered. After 10 seconds without programming or by quickly pressing the programming button or pressing the first two transmitter
buttons, the equipment will exit programming mode, issuing two 1 sec. acoustic signals.
Total reset
In programming mode, the programming button is held down and the "MR" reset jumper is bridged for 3 secs. The equipment will issue
10 short acoustic warning signals followed by others at a faster pace to indicate that the operation has been successful. The equipment
is now in programming mode. The pilot programming light will also follow the acoustic indications by flashing.
After 10 seconds without programming or quickly pressing the programming button, the equipment will exit programming mode, issuing
two 1 sec. acoustic signals.
UM_3200436_VAR-R15_5ID_Rev01
ERROR led
SAFETY led
(Code)
on
on
(255)
1 flashes
1 flashes
(17)
2 flashes
2 flashes
(34)
off
1 flashes
(16)
off
2 flashes
(32)
off
3 flashes
(48)
off
4 flashes
(64)
1 flash
off
(1)
2 flashes
off
(2)
3 flashes
off
(3)
4 flashes
off
(4)
5 flashes
off
(5)
6 flashes
off
(6)