LIGHT INDICATORS
Function
Indicates
POWER
Power
SAFETY
Operating alert (see table)
ERROR
Operating fault (see table)
TIMER
Operation programming mode
PROG
RADIO
Radio programming mode
PROG.
BUTTONS
START
Start
TIMER PROG.
Start pulse or time programming
RADIO PROG.
Start transmitter programming
Programming
· If stoppage is required during programming, the control panel exists programming automatically for safety reasons.
· Before starting any type of operation programming, the corresponding options must be correctly selected (option switch, input switch
and option switch bridging) and the safety elements must be connected, where applicable.
· Operations can be programmed indifferently using the TEST / START button or through a previously programmed transmitter.
· If in programming mode for 30 seconds without programming, the equipment will exit programming mode and the TIMER PROG. led
will switch off.
Self-programming (Option switch 1 at ON)
Press the TIMER PROG button to enter programming. The TIMER PROG led with light up. Use the TEST or the START button or a
transmitter to start programming the run. After the button is pressed for the first time, the door will open slowly (if option 4 of the
options switch is turned to ON) until a mechanical stop is reached or the Open limit switch is enabled. It will then close until it reaches
a mechanical stop or the Close limit switch is enabled. Immediately afterwards, the panel begins to operate, carrying out all of the
operations programmed and memorising the consumption of the runs. Once consumption memorising is complete, the TIMER PROG led
will switch off.
The panel is programmed with the following fixed parameters: Slow-speed operations are 15 % of total operations, partial opening is
equivalent to 2/3 total opening and the automatic closure standby time is 30 seconds (total opening and partial opening).
N.B.: Where limit switches or mechanical stops are not used on either of the two ends of the door, the START button must be pressed to
indicate the limit of the run at the end of the door without the limit switch or mechanical stop.
Manual programming (Option switch1 at OFF)
Press the TIMER PROG button to enter programming. The TIMER PROG. led with light up. Use the TEST or the START button or a
transmitter to programme the run. The first time the button is pressed, it opens. After the button is pressed for the second time, the
opening movement will slow down (if option 4 of the options switch is turned to ON) until a mechanical stop is reached or the Open limit
switch is enabled and the automatic standby timer will begin. The third time it is pressed, it stops the automatic standby timer and
closes. After the button is pressed for the fourth time, the closure movement will slow down (if option 4 of the options switch is turned to
ON) until a mechanical stop is reached or the Open limit switch is enabled. Immediately afterwards, the panel then begins to operate,
carrying out all of the operations programmed and memorising the consumption of the runs. Once consumption memorising is complete,
the TIMER PROG led will switch off.
N.B.: Where limit switches or mechanical stops are not used on either of the two ends of the door, the START button must be pressed to
indicate the limit of the run at the end of the door without the limit switch or mechanical stop.
Partial opening programming
In programming, use the second recorded transmitter channel button to programme partial opening. Then programme as required using
the steps described above.
Basic parameter of the variable speed drive
The modification of some of the variable speed drive parameters non-described below can carry to a bad operation or blocking of the
equipment. These parameters should only be handled by a specialist fitter or by a suitably trained operator.
Parameter
Function
Pr03
Acceleration rate (seg/100Hz)
Pr04
Deceleration rate (seg/100Hz)
Pr06
Motor rated current (A)
Pr07
Motor rated speed (rpm)
Pr08
Motor rated voltage (V)
Pr09
Motor power factor (cos )
Pr18
Preset speed 1 (fast) (Hz)
Pr19
Preset speed 2 (slow) (Hz)
UM_3200436_VAR-R15_5ID_Rev01
Default status
Normally on
Normally off
Normally off
Normally off
Normally flashing
TIMES
Controlling
Motor operating
Wait for automatic close
Default value
2
2
4
1500
230
0,85
50 (Hz)
16 (Hz)
OPTION SWITCH BRIDGING
JP1
Integrated radio disconnection (where a pluggable receiver card is used, the
cut bridge provides greater range)
JP2
Pedestrian channel disconnection of the pluggable receiver card (where a
single-channel RACK+DCS is used, this bridge must be cut)
JP3
Select the operation by pulses or by time. With the jumper at ON the panel
operates by pulses and with the jumper removed it will operate by time.
JP4
Without function
Minimum Maximum
3s
3s
It is recommended to modify the parameters 06, 07, 08 y 09
according to the used motor type and model. These parameters
are showed on the motor.
For modifying any parameter you should introduce the following
password: 231
10min
10min
Page 7/21