SCANGRIP UNI-EX Manual De Instrucciones página 3

Ocultar thumbs Ver también para UNI-EX:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
CRI (Ra):
CCT:
IPXX:
Operation Temperature(°C):
Storage Temperature(°C):
Product Dimension:
Product Weight:
3. Usage and Application Scope
UNI-EX 03-5617 of Handheld Rechargeable Work Light is a rechargeable and portable explosion-proof handle light
(abbre.Explosion-proof light in the following instruction), suitable for using in explosive area of Zone 0, Zone 1,
Zone 2, Zone 20, Zone 21, Zone 22, gas group IIA/IIB/IIC, dust group IIIA/IIIB/IIIC and Temperature Group T1~T3/
T130 °C. It is suitable for using in temporary local auxiliary lighting and local main lighting for the industries of
petroleum produce, smelting, chemical, pharmaceutical, brewing, military reserve, etc.
4. INSTRUCTION
• Before use, please check whether the packing is in good condition, if there is any visible damage of the light and
charging base. For the handle light, please check if there is any visible damage of the structure or "abnormal
sound" inside. Please open the light to check if the damage will influence the explosion-proof performance and
make appropriate treatment.
• Please check if the explosion-proof light nameplate parameters listed are conformed to the actual conditions of
use.
• The explosion-proof light is composed of handle light, charging base and adaptor.
• The explosion-proof light is with magnetic base, foldable stand and hook. It can be adjusted in different direction
and easily, quickly use with the hook.
• The explosion-proof light is with four modes: Top, Low, High, OFF. Press first "Top", second "Low", third "High",
fourth "OFF".
• Please charge the light under the circumstance between 0° C to +45° C. Please pay attention to the orders when
charging. First, please make sure the effective connection between the light and charging base. Second, plug the
adaptor to AC power supply. The conversed operation is prohibited.
• The explosion-proof light is with the function of battery capacity indicating. Press the "switch" for 3 seconds,
"battery capacity indicator" will show the current battery capacity. When it shows "
time. When it shows "
• The following operations are prohibited in any possible dangerous area:
Open the light when it is working or turning off the load.
Regular or occasional maintenance and repair.
• Operating under explosive atmosphere, fasten protection cap of charger, do not open the protection cap under
explosive atmosphere.
• The persons who use the light at site should know about the performance of explosion-proof light. Turn off the
light in time and evacuate the dangerous area when find any abnormal phenomenon. Unqualified repair person is
not allowed to repair the explosion-proof lights.
5. MAINTENANCE
• When installation, use and maintenance, observe following standards IEC 60079-10, IEC60079-14, IEC60079-17
and IEC 60079-19
• The service man must have on-the-job training to know the specification and operating performance of
explosion-proof light. They must have professional knowledge and should familiar with the structure of
explosion-proof light.
• Clean the dust and dirt on the shell of the explosion-proof light regularly to improve the luminous efficacy and
heat dispersion performance. A wet cloth can be used for cleaning.
• Check whether the transparent parts have been impacted by foreign body regularly. Check whether the fasteners
and inner components are loose, soldering off or corroded. If yes, do not use it until maintained.
• If use the light in damp environment, please regularly check and change the sealing components to ensure the
protective performance of the shell.
• When disassemble the light, must comply with the warning requirements to operate in non-dangerous area.
• After open the shell, should check whether the sealing components become hard or adhesive; whether the
insulating layer of the wire become green or carbonized; whether the insulating parts and electrical components
become deformed or have scorch. If these problems are found, must repair the light immediately.
>80
5500K~6500K
IP65
-20°C~+45°C
-20°C~+45°C
L220*W70*H39 mm
436g