Interlogix VE700AM Serie Manual De Instalación página 11

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Enabling walk test will not clear the alarm memory.
Disabling walk test will cause the indication of
memorised alarms to reappear.
Selecting the coverage pattern
See Figures 21 and 22.
The coverage pattern can be changed to fit specific
requirements by using the mirror stickers
(enclosed), as shown. We recommend that you
blind unused curtains that are looking at objects
located very close to the detector.
Caution:
Removing the stickers can damage the
mirror surface.
Blocking the curtains
See Figure 23.
The mirror blinders are fitted on the mirror by
default. To remove a blinder, first remove the
interior part of the detector. Then lift the lower part
of the blinder and wiggle the upper part to loosen it.
When long-range detection is not required (>20 m /
65.6 ft.), remove the long-range mirror (Figure 24).
Pry-off and cover tamper
The detector has both pry-off and cover tamper
(EN 50131-2-2 compliant).
It is important to use the screw indicated in Figure 4
in order to ensure pry-off tamper.
For corner-mount applications, use the ST400 for
pry-off tamper (Figure 25). However, see the note
listed in "Mounting the detector" on page 6.
Pry-off tamper and ST400 are not evaluated by UL.
SB01 swivel-mount bracket (optional)
When it is not possible to mount the detector on a
wall, use the SB01 to mount it on the ceiling.
See Figure 26.
SB01 swivel-mount bracket is not evaluated by UL.
Remote and self-testing the detector
There are two causes for technical faults.
It is caused by continuously monitoring the pyro
and the AM circuit reference levels.
It is caused by the self test and the remote test.
P/N 149973999-3 (ML) • REV D • ISS 17OCT13
Remote test: This test allows the VE700AM to be
tested from the control panel. Use terminal 12 to
activate it. The VE700AM will activate the alarm
relay if the test result is positive and the AM relay if
the test result is negative.
Remote test
Terminal 12:
Alarm relay:
AM relay:
Self test: The VE700AM monitors the PIR and AM
circuits continuously. A defect is reported as a
technical fault.
Self test
PIR*:
8 h
AM*:
VE700AM OK
8 h
AM relay:
* Starts 1 hour after installation.
Technical fault reset
A technical fault detected by continuous monitoring
can be reset in two ways.
Authorised reset. Set the system to day and
walk test status and then carry out a walk test.
At the next PIR alarm the system resets if all
reference levels are within the specified limits.
Auto reset. After a 40-second inhibit period, it
automatically resets after a successful walk test
if all reference levels are within the specified
limits.
A technical fault detected by a self test or a remote
test can only be reset by another self test or a
remote test if the test is successful.
3 s
VE700AM OK
VE700AM not OK
8 h
8 h
VE700AM not OK
11 / 80
loading