DONNING
Note: The PAPR must have gone through
a pre-use check in accordance with the
Operating and Maintenance Instructions
manual prior to use.
The breathing hose must be attached to the
blower prior to donning the Headtop - See
Operating and Maintenance Instructions.
Glasses may not be worn with the FM4
except by utilising the internal frame
designed for this mask.
When worn correctly the headtop will be
comfortable and a full range of motion
will be achievable.
Turn the head harness inside out and
over the front of the headtop
Offer the mask up to the face with one
hand, chin into the mask seal
With the other hand pull the harness
from the front of the facemask and
over the back of the Head. Smooth
the harness out ensuring that the head
harness does not ruck or tangle
Tighten the bottom two buckles, then the
middle two and finally the top buckle
Test for a good range of motion. The
faceseal should remain in contact with
the face
DOFFING
CAUTION: do not remove the headtop
until you are in a safe and hazard free
zone
Once free of any hazard switch off the
PAPR in accordance with the operating
and maintenance instructions
Ease the head harness buckles towards
the front of the headtop to fully release
the headtop harness tension
Pull the mask over the head and
remove the headtop
Place the headtop onto a clean surface
Remove the PAPR in accordance
with the Operating and Maintenance
instructions
Proceed with after use cleaning and
storage
FM4
AFTER USE CLEANING
Note: If during use the equipment
may have become contaminated by
hazardous substances, the contamination
must be identified and properly removed
or the contaminated components must
be replaced before next use.
Disposal of the contaminated components
must be carried out in accordance with
local regulatory requirements.
Disconnect the breathing hose from
the blower
Inspect the equipment for worn,
ageing or damaged components
Carefully wipe clean the headtop with
a warm water solution containing a
mild detergent
It is recommended that headtop visors
be wiped clean with Distel® wipes
If necessary, wash the outside of the
breathing hose carefully using warm
water solution containing a mild
detergent
Ensure the breathing hose connections
are free from all dirt or debris that
could prevent an effective seal with the
blowerl
Once clean all components must be left
to dry naturally.
STORAGE
Device must be protected from damage
during transportation.
once all the components are clean and
dry store in a clean environment.
SPARES
replacement parts and accessories
may be ordered through Scott Safety
customer services. The department
can also provide general information on
other Scott Safety products.
Scott Safety
www.scottsafety.com
Tel: 131 772
Fax: 1800 651 772
6