MAINTENANCE
If the beer cooler does not work properly, please call the service center;
To save time and money, before you call for service, check the
Troubleshooting Guide. It lists cause of minor operation problems that
you can correct yourself.
Trouble
The tap does not
work / can't pour
beer out
Too much bubble
pouring out
Beer flows out too
slowly
Cause
1. The pouring tube is in poor
connection or CO2 supplying is
cut off
2. No keg or no beer in the keg;
3. No gas in the CO2 cartridge
4. The CO2 pressure regulator
knob is close
1. Use a wrong way to pour beer
out
2. The beer temp is high (better at
3-5C)
3. The keg is shaken before usage
4. Almost no beer in the keg
5. Too much pressure in the keg
1. Inside CO2 pressure isn't high
enough
2. The
connection
pouring tube has leakage
1. Well connect the pouring
tube and CO2 supplying
2. Change a new keg
3. Change a new CO2
cartridge
4. Turn the CO2 pressure
regulator knob on "+" position
1. Use the right way to pour
beer out
2. Cool the beer down to 3-5C
3. Put the beer keg aside a
while till no bubble inside
4. Change a new keg
5. Adjust the pressure knob to
"-" direction to decrease the
pressure or close the knob
1. Adjust the pressure knob to
release much CO2 pressure or
tube
or
replace a new one.
2. Check whether the tube is
leakage or not, if so replace
the tube
Troubleshooting