Teclas
Parámetro
Volumen
[Agility 1.4]Definir el volumen del sonido de alarma de la sirena
interna. Los valores posibles son 0 (silencio) a 9 (Máx volumen).
Después de definir/cambiar el volumen, la sirena emitirá un
sonido con objeto de poder evaluar el nivel de sonido
seleccionado.
Lamp[5IN1344 L8PSProgInst [8][4][1][5]]
Defines the way the external lamp will be operated
Tipo
SIEMPRE ON–The lamp is always on.
ALWAYS OFF–The lamp is always off.
SCHEDULER– The lamp operates according to the time
defined under the Sounder Lamp menu (Quick Key:
).
Intensidad iluminación
(01–10%)
Used to set the brightness level of the external lamp.
Power Source
[5IN1344 L8PSProgInst [8][4][1][7]]
Used to define the SAB or SCB power source mode of the
LuMIN8.:
SAB—Power supply for the sounder will be drawn from the
control panel.
SCB—Power supply for the sounder will be drawn from the
sounder's rechargeable battery.
Siren Current
[5IN1344 L8PSProgInst [8][4][1][8]]
Set the sounder current mode.
BAJO – The sounder output will be reduced to 106dB 150mA.
ESTANDAR ‐ The sounder output will be 112dB 350mA
(assuming single piezo head).Specify the siren current level:
Por defecto
9 (0‐9)
Programador horario
[5IN1344 L8PSProgInst [8][4][1][6]]
Standard Standard/Low
Página 225
Rango
05
SAB