Black and Decker BDFH44M Manual De Instrucciones página 26

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
3 Wire Direct Connections
1. Move the neutral grounding wire (white) to the green ground connector
2. Connect the neutral wire (center wire) to the center terminal
3. Connect the remaining 2 wires to the terminal block screws on both sides.
4. Securely tighten all electrical connections.
5. Replace the terminal block cover.
WARNING:
A Outer terminal block screws
B Live wire
C Neutral wire (center wire)
D Neutral grounding wire (white)
E Green ground screw
4 Wire Direct Connections
1. Connect neutral wire (white or center wire) to center terminal.
2. Ground wire (green or bare wire) must be connected to green ground connector.
3. Connect remaining two supply wires to remaining two terminals.
4. Securely tighten all electrical connections.
5. Replace the terminal block cover.
WARNING:
A Outer terminal block screws
B Live wire
C Neutral wire (center wire)
D Live wire
E Green ground screw
For a permanently connected dryer:
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run with the circuit
conductors and connected to the equipment-grounding terminal on the appliance.
WARNING:
risk of electric shock. Check with a qualified electrician, or service representative or
personnel, if you are in doubt as to whether the appliance is properly grounded.
WARNING:
SERVICING. This dryer should be connected to an individual branch circuit with 10
gauge copper wire minimum through a 30 amp fuse or circuit breaker. DO NOT fuse
neutral. Use copper conductors only.
Page 26
Failure to do so can result in death,
fire or electrical shock.
Failure to do so can result in death,
fire or electrical shock.
Improper connection of the grounding conductor can result in a
TO PREVENT ELECTRIC SHOCK, DISCONNECT POWER BEFORE
C
D
E
D
Black
White
E
A
B
A
B
Red
Green
C
loading