F2:
With the F2 option, you can set the negative
Setting
Setting
pressure in your tent by decreasing the speed
Exhaust Fan
of the intake air fan. Press ENTER on "Intake
(F1)
Fan(F2)" and you will land on the page where
you can set the negative pressure that you'd
Intake Fan
like in your grow tent. Press ENTER and use
(F2)
the UP and DOWN arrows to select your
number, press ENTER again to confirm the
selection.
You also have the option to not let your intake fan activate when your
temperature and/or humidity falls below the setpoints. This function will
run in conjunction with the F1 settings and gives you the ability to choose
whether you want to run the F2 fan at minimum speed % or turn the fan
off completely. Press ENTER on the bottom square next to "Stop fan
below setpoint" and it will start blinking. Use the UP or DOWN arrow to
allow the check mark √ to appear on the screen, press ENTER again to
confirm the selection.
System Settings:
The "System" tab is where you will set your miscellaneous internal
settings for your Tent-X Controller.
First, set your unit of measurement for the temperature and EC, and your
time settings. Next, you can also manually override your controller on this
page if you'd like to test and make sure everything is connected and
working properly with the controller, as well as scan the QR code to pair
your smart device with the controller, or do a complete system reset if
there's a need to do so.
EC Fan Control
Moreover, set the ADJUSTABLE VARIABLE
RANGE for your temperature and humidity in
Temp Variable
the EC Fan Settings tab. When the set
Range
parameters are exceeded, the exhaust will
3
C
o
start operating at maximum speed set by the
Humid Variable
user in F1 settings, and gradually resume to
Range
minimum speed set by the user, in a linear
5 %
fashion.
In addition, you can calibrate the various sensors you are using inside of
the grow tent. Furthermore, on the System page, you can set your
deadband setpoints that will be used with your connected DS modules.
The deadband settings determine when each module will turn on, and
turn off again.
08
Lastly, you can set your Water detectors in case of leakage or water
confirmation, and your WD delay time., On the Alarm setting page, you
can set your high and low limit alarm settings for your climate, nutrients,
and grow medium. When the values exceed or drop below the defined
Maximum and Minimum setpoint in the alarm settings, you will immedi-
ately be notified on the controller and through TrolMaster's app, TM+
Pro.
SPECIFICATIONS
Input Voltage:
Certifications:
MBS-TH (Temp / Humid / Light):
MBS-S8 (CO2):
MBS-PAR (PPFD):
MBS-SD (Smoke Detector):
AMP-3 (pH / EC / Temp):
WCS-1/2 (WC / EC / Temp):
WD-1 (Water Detector):
Temperature Device Stations:
Humidity Device Stations:
CO2 Device Stations:
Timer Device Stations:
EC Fan Control Adaptor:
Working Environments:
WARNING :
DO NOT allow the TCS-1 to be exposed to water or
excessive heat. DO NOT open or attempt to repair or disassemble
the controller, as there are no user-serviceable parts inside.
Opening the controller will void the warranty.
If the surface of TCS-1 is dirty, wipe it with a dry towel. The TCS-1
operates under natural ventilation conditions.
AVERTISSEMENT :
NE PAS exposer la carte de contact sec TCS-1 à
l'eau ou à une chaleur excessive. NE PAS ouvrir ou tenter de réparer
ou de démonter le contrôleur, car il ne contient aucune pièce
réparable par l'utilisateur. L'ouverture du contrôleur annulera la
garantie.
Si la surface de la carte de contact sec TCS-1 est sale, essuyez-la
avec une serviette sèche. La carte de contact sec TCS-1 fonctionne
dans des conditions de ventilation naturelle.
100-240VAC, 50/60Hz
ETL/FCC
max 1pc per set
max 1pc per set
max 1pc per set
max 1pc per set
max 1pc per set
max 1pc per set
max 2pc per set
max 2pc per set
max 2pc per set
max 2pc per set
max 4pc per set
max 2pc per set
Temperature 32-122°F, Humidity≤90%
09
loading