Cleaning and maintenance
Replacing the cartridge
1. Shut off the water supply to the faucet.
2. Turn on the faucet briefly to relieve any
pressure inside the faucet.
3. Move the faucet handle to the "OFF"
position.
4. Remove the set screw from the Handle
Assembly (A) using a 2.5 mm hex key.
5. Pull the Lever Handle (A) and Cartridge
Cap (B) from the faucet body.
6. Unscrew the Cartridge Lock Nut (C).
7. Lift ceramic Disc Cartridge (D) from
the body and replace it with a new one.
Ensure the two lugs on bottom of the
cartridge sit properly in the allocated
holes at the base of the body.
8. Re-assemble faucet in reverse order.
9. Test for leakage.
General maintenance
Clean aerator periodically for any buildup
(fig. 2D and 2E).
Do not use harsh detergents, solvents,
chemical agents, especially CHLORINE
or metallic sponges as these can damage
the surface finish. Clean only with a soft
sponge and soapy water.
Do not store chemicals or cleaning
agents in the immediate vicinity of the
faucet and connection hoses. Chemical
vapors could cause damage.
D
C
30 mm
106 in-lbs
7
B
A
EN
2.5 mm