TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON'T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
TROUBLE PROBABLE CAUSE
Unit may be defective
Power supply
is on, no light
are lit.
Lost of prime due to a low water level
Power supply
condition
is on, pump on
Water pipe obstructed from water supply
light is off,
to pump
failure light
Power cut-off by thermal protector
is on.
Pump cannot reach proper minimum
operational pressure
Loss of pressure due to leak in the piping
Power supply
is on, pump on
light is on,
failure light is
off, and pump
short cycles On
and Off.
The water column to the highest tap
Power supply
exceed 50 feet
is on, pump on
light is on,
failure light is
off, tap is open
and no flow.
Pump is off.
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
10
FLUOMAC
ACTION
Test electrical terminals with
voltmeter. If there is no power, replace
the unit
Wait for water level resume and press
reset button
Clean obstruction and press reset button
Wait 10 minutes and press reset button
Clogged pump nozzle and/or
venturi, clean and press reset button
Make sure all taps are closed and all toilet
valves are functionning
If leak not found, install a back valve after
the Fluomac. If cycling stops, leak is at the
supply line. If cycling occurs, leak is at
suction line. Foot valve may be defective
or clogged. Replace.
Pressure of water column is higher the
cut-in pressure (26PSI).
Re-install the unit at a higher level