Pentair Flotec SIMER FP4322-08 Manual Del Propietário página 9

Idiomas disponibles

Idiomas disponibles

ELECTRICAL
MOTOR SWITCH SETTINGS
Risk of electric shock. Can shock, burn or kill.
Disconnect power before working on pump, motor, pressure
switch, or wiring.
NOTICE 1/2 HP motors are dual voltage and are factory set to
115 V. 3/4 & 1 HP motors are also dual voltage, but are factory set
to 230 V. Motor terminal boards (located under the motor end
cover) should look like one of those below. Use the instructions
to set your motor to match your power source.
RISK OF ELECTRIC SHOCK . Can shock, burn or kill.
NEVER connect a motor set to 115 V to a 230 V power source.
PLUG TYPE VOLTAGE SELECTOR
Voltage Change Plug
Ground Wire Connection
Figure 14 - Voltage set to 230 V, Plug Type
Voltage is set to 230 V To change to 115 V:
1.
Make sure power is off.
2.
Pull the voltage change plug off of the tabs.
3.
Move the voltage change plug to the 115 V position. The plug
will now cover 2 metal tabs and the arrow on the plug will
line up with the 115 V arrow on the label.
Figure 15 - Voltage set to 115 V, Plug Type
P15003 (12-15-22)
Power Connections
Pressure Switch
4530
4.
Attach the incoming power leads to the two outer screws
on the pressure switch as shown in Figure 14.
5.
Attach the ground wire to one of the grounding
connections, shown in Figure 14.
6.
If there are other wires, they should be capped.
7.
Reinstall the motor end and pressure switch covers.
DIAL TYPE VOLTAGE SELECTOR
Figure 16: Voltage set to 230 V, Dial Type
Voltage is set to 230 V To change to 115 V:
1.
Make sure power is off.
2.
Turn the dial counter-clockwise until 115 shows in the dial
window as shown in Figure 17
Figure 17 - Voltage set to 115 V, Dial Type
3.
Attach the incoming power leads to the two outer screws
on the pressure switch as shown in Figure 16.
4.
Attach the ground wire to the grounding connections as
shown in Figure 16.
5.
If there are other wires, they should be capped.
6.
Reinstall the motor end and pressure switch covers.
9