Thank you for using a KABI product!
Read this manual carefully prior to using the pump.
Please forward this manual to all other users, to make
them aware of all warnings and specifications.
Content
Pump specifications
Warning!
I. Operating manual
II. Maintenance of the pump
III. Rectifying an error
Pump specifications
Self-priming diaphragm pump EPDM, 1" ext. thread.
IP55 enclosure.
Operating pressure: 3 bar / 40 Psi.
Temperature: min. -5°C / max. +40°C.
Moisture: max. 90%.
Sound level: 70 dB.
Self-priming up to 4 mtr. vertically.
Duty cycle: continuously.
WARNING!
• Do not use for petrol, flammable liquids, corrosive
chemical products or solvents.
• Not suitable for pumping liquids with a viscosity
> 20 cSt.
• Do not use in hazardous areas.
• Improper use or installation of this product can
result in serious injury or death.
lll. Rectifying an error
Problem
Pump does not run
Low or no pump capacity
KABI AdBlue® diaphragm pump
l. Operating manual
(A) Before using the pump
(B) Installation of the pump
(C) Operating instructions
ll. Maintenance of the pump
Possible cause
No power
The rotor is stuck
Motor problems
Blockage in the suction hose
2.
1. Ensure the machine has not been damaged
during transportation or storage.
2. Clean the inlet and outlet openings and remove
any dust or packaging residues.
3. Check that the electrical specifications correspond
to the values on the rating plate.
1. Use only inlet and outlet hoses or tubes that are
compatible with AdBlue® / AUS32. Tighten the
fittings (inlet/outlet at the pump, 1" (F)).
2. Use a nozzle or a valve at the end of the hose that
can be closed, in order to prevent liquid leaking
out when the pump is not in use.
3. We recommend you to use KABI's accessories.
1. Turn on the pump.
2. Pull the nozzle lever to drain the liquid.
3. When the desired amount of fluid has been
dispensed, release the nozzle lever, remove the
nozzle and switch off the pump.
4. The nozzle should be kept clean and dry, and
securely fastened when not in use.
1. Make sure the hose connections are tight, to
avoid wastage.
2. Keep the pump unit free of impurities.
3. Do not connect the power cables, if they are in
poor condition.
Check the electrical connections
Check whether the rotating
parts are damaged or obstructed
Contact the service department
Check the tank and the inlet hoses
Remedy