21.10.01.00065/02
Diagnostic Buffer - Details
Data Format of Single Entry (ISDU 132)
Bytes 0...1
Bytes 2...5
Diagnostic-Type (MSB first)
Counter cc1 (MSB first)
Data Format of Diagnostic Buffer (ISDU 131)
Bytes 0...5
Bytes 6...11
Bytes 12...17
Entry 1 (newest)
Entry 2
Entry 3
Encoding of Diagnostic-Type
Diagnostic-Type
Description
Notifications
0x1401
Notification: Device powered on
0x1402
Notification: Diagnostic buffer cleared
0x1403
Notification: Parameters restored to factory defaults
0x1404
Notification: Vacuum sensor calibrated successfully
0x1405
Notification: Manual mode entered
0x0405
Notification: Manual mode exited
0x14AA
Notification: Corrupted entry
J. Schmalz GmbH
...
Bytes 223...228
...
Entry 38 (oldest)
9 of 11
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
Remark
Counter value cc1 of when the entry was recorded
Remark
Buffer of 38 entries (newest to oldest) with encoding as in ISDU 131
Remark
Single entry was written incorrectly - do not evaluate