8.
TROUBLESHOOTING
Warning!
Montage, upkeep and service need to be conducted by a qualified professional with appropriate
qualification, an appropriate company or the gas supplier.
PROBLEM
SMELL OF GAS
Leak detected at cylinder,
regulator or other connection.
Burner does not ignite
Igniter Not Working
Low efficiency, „cracking"
sounds
Thumping sounds made by the
regulator.
A vivid/ bright orange and
smoky flame of the burner.
9.
TECHNICAL SPECIFICATION
Applianace Category
Reference gas
Inlet pressure
Injector diamater
Gas consumption
Nominal Heat Input (Hi)
Nominal Heat Input (Hs)
Safety device
Gas control valve
Flexible hose (1,4 m)
POSSIBLE CAUSE
CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY. DO NOT USE
THE DEVICE UNTIL LEAKS HAVE BEEN REMOVED.
1. A loose regulator linkage.
2. Leak in the gas linkage, in the regulator
or on the gas knobs.
1. The bottle is empty.
2. Igniter linkage is not connected.
3. No ignition spark.
4. The igniter electrode is placed
incorrectly opposite the igniter.
5. Gas nozzles are blocked.
6. Gas linkage is twisted.
7. Pressure regulator link is loose.
1. Ignitor wire not connected.
2. Electrode misaligned on pilot burner
3. Igniter malfunction
4. The battery has run out
1. The bottle is empty.
2. The nozzles of the burner are blocked.
The cylinder valve has opened rapidly.
Holes blocked in the apparatus producing
the gas and air mixture.
I3P
G31
[mbar]
30
37
[mm]
1,2
[kg/h]
0,4
0,45
[kW]
4,5
5,0
[kW]
5,0
5,5
1. Tighten and test it.
2. Report this issue to service.
1. Replace Gas Cylinder.
2. Connect the igniter linkage.
3. Replace igniter.
4. Realign electrode and clear any
surrounding debris from area.
5. Unmount burner, clean the nozzle.
6. Straighten the linkage. Keep the linkage
away from the housing.
7. Tighten the link. Check for leaks.
1. Ensure pilot electrode wire is connected.
2. Realign electrode and clear any
surrounding debris from area.
3. Replace Igniter
4. Replace battery
1. Replace Gas Cylinder.
2. Unmount the burner, clean the nozzle.
Unfasten the bottle valve slowly.
Unmount the burner and clean/ unblock the
apparatus' holes.
I3B/P
G30
50
30
37
1,2
0,5
0,4
0,45
6,4
5,1
6,4
7
5,6
7
Thermocouple
BS190
Ø9mm
18
CORRECTIVE ACTION
I3+
G30
50
28-30
1,2
0,5
0,4
7,4
5,1
8
5,6
G31
37
0,45
5,1
5,6