Gas cylinder connection
Twist-on connection
1. Check if the bottle valve is TURNED OFF turning
it clockwise
2. Remove the protection tip and store it for later
use.
3. Before making the connection check if the black
seal is not damaged.
4. Fit the connecting nut to the cylinder with the
use of a correct wrench or the connecting knob.
(left thread) Do not allow the gas bottle
connectors to be fastened too tightly.
5. When the gas flow is required turn the valve of
the bottle counter-clockwise.
WARNING!!!
Check the gas connection for leakage. If anything suggests a leak is present (for instance a
characteristic gas smell) close the gas bottle valve and under no circumstances turn the device on before removing
the leak.
After removing the leak one may open the gas bottle valve again.
Quick-release
1.
Remove the protection tip. Do not use any tools,
leave the tip hanging freely.
2. Make sure all the taps on the gas device are
closed and if the switch in in the OFF position.
3. Place the quick-release regulator on the valve
and press it down hard. If the switch is correctly
turned off you will hear a characteristic click.
4. To let the gas flow in turn the switch into the ON
position (or into the flame image).