House Side Shield for COB Configurations
Tools Required
#2 Phillips head screwdriver and pliers.
1.
Remove plastic push pins on back side of optic.
(Figure 14).
N
ote:
DO NOT try to remove the optics. The optics are not
rotatable. Rotated optics must be factory ordered.
2.
Install house side shield with provided Phillips screws.
Tighten until house side shield is snug. Do not
overtighten.
House side shield must ONLY be installed on the
N
ote:
back side of the optics as shown. DO NOT install on
the other side of the optic. (Figure 14)
House Side Shield
Figure 14.
House Side Shield for Discrete Panel Configurations
Tools Required
Torx screwdriver and pliers.
1.
Remove the six torx type screws around the optics.
DO NOT try to remove the optics. The optics are not
N
ote:
rotatable. Rotated optics must be factory ordered.
2.
Place house side shield over the optics. All six screw
holes will align with the optic if the house side shield is
installed correctly. (Figure 15)
The light will shine out of the rounded portion of
N
ote:
the lens. The sharp vertical portion of the lens is the
house side of the lens.
3.
Re-install all six torx screws and torque to
10 to 15 in-lbs. (Figure 15)
Installation Instructions – Prevail Petite / USSL Petite
Figure 15.
Photocontrol Orientation (If Equipped)
Tools Required
Screwdriver
The orientation procedure is only required for photocontrols
which specifically require the cell to be aimed north.
Otherwise pre-selected factory orientation will function
properly. Follow the directions recommended by the
photocontrol supplier for proximity to light sources. Lighted
signs, building surface reflection, floodlights, tree branches,
etc. may affect final position of the photocontrol.
1.
Loosen the two screws to allow rotation of the
receptacle.
2.
Insert screwdriver into center slot and rotate receptacle
until indicator arrow points north.
3.
Retighten screws.
4.
Insert the photoelectric control (or shorting cap) into
receptacle and twist into locked position.
The photocontrol (not included) must contain a soft,
N
ote:
resilient gasket fastened to the bottom surface to
assure a proper weather seal between the control
and the receptacle.
Loosen
Screws
Figure 16.
Cooper Lighting Solutions
House Side
Shield
Torx Screws
Insert Flat Head
and Rotate
IB514105EN
Installation instructions
5