5. ELECTRONIC TOUCH PANEL WITH
CONTINUOUS MODULATION
The electronic TOUCH panel allows the temperature to be adjusted using the AUTOMATIC,
NIGHT and BOOST programs.
The control panel has a memory, meaning all settings can be stored and will not be lost in case
of a power outage.
After a period of 20 seconds from the last action, the lighting in the panel is
dimmed specifically to guarantee the maximum energy savings and comfort at night time. The
display shows the ambient temperature.
When any button is pressed, the maximum brightness is restored.
A 10 kΩ water temperature probe in the fan coil of the appliance allows RELAX HYBRID to
control the minimum temperature for heating (30°C) and the maximum for cooling (18°C).
A clean contact control allows the radiator to switch the system circulator on and off.
DISPLAY
5.1 DISPLAY
The display also shows the states and any alarms, using specific symbols:
58
!
!
Heating on
Cooling on
Function not used
Alarm indication (steady light)
!
Boost function
Night-time function
Automatic function
Function not used
Panel off indication
BUTTONS