B 423192151219082015

WARNINGS

EThe range hood is designed and manu-
factured according to DS/EN 60335-1.
This range hood is only for use in private
house holdings, if used for other purpo-
ses the warranty will be repealed.
Installation must be performed by a skil-
led electrician in accordance with the
specifications given by Thermex Scandi-
navia A/S (Thermex) and legislation in
force.
Thermex disclaims all responsibility in re-
gards to damages caused by wrong in-
stallation, mounting or use.
BEFORE MOUNTING/COMMISSIONING
Inspect the range hood for transport da-
mages, flaws and defects immediately
after the receipt.
Transport damages must be filed to the
haulage contractor and Thermex imme-
diately after the receipt.
Flaws and defects must be filed to Ther-
mex within 8 days the receipt, and not
later than mounting/commissioning.
MOUNTING
The range hood is intended for working
at 230 Volt ±10%~ 50 HZ ±10% in refer-
ring to EN 50160.
The range hood must have earth.
For models with external motor applies
that NOT to use common zero by instal-
ling the hood and engine, as this will af-
THERMEX NEWCASTLE 55
fect the control.
It MUST be ensured that the motor can
be used with the selected range hood
when using an external motor from
another supplier. Otherwise the warran-
ty no longer apply.
Do not plug in the range hood until the
mounting is complete.
The air must not be discharged from the
hood into a pipe used for extraction from
devices using gas or other fuels. Such de-
vices must have a separate vent.
The national legislation on air emissions
must be observed.
Always use the original dimension of the
vent. By reducing the dimension of the
vent, the performance will be reduced
and the sound level will be increased.
The vent to the open air, must be as
short as possible in order to get the grea-
test possible capacity of the range hood.
The number of bends on the vent ought
to be minimised, to gain the greatest
possible capacity of the range hood.
Thermex recommends to always use
sound and condensation insulated vent
hose at the carrying through in unheated
spaces.
Thermex recommends that there is used
for a muffler to minimize the noise level
when using flexible hose.
Using the flexible hose must always en-
sure that this is fully extended to mini-