BFT ARGO BT A 20 Instrucciones De Uso Y De Instalacion página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
x2
***
0---
10--
Add. 1ch
hidden butt
Add. 2ch
hidden butt
Add. 3ch
hidden butt
Add. 4ch
hidden butt
erase 64
erase 1
( 0001 )
language
Fig. G
autoset
phases 8 --> 13
Fig. G
reg fc
phases 1 --> 7
Control unit
software version
stat
vers
OK
bft . . .
+/-
- +
No total manoeuvres(in hundreds)
n. cycles
OK
0000
+/-
- +
No radio controldevices memorised
OK
00
n. remotes
+/-
- +
List of last 30 errors
err
OK
01. 3 3
02. 0 1
........
30. 1 5
+/-
0---
password
ACCESS MENUS Fig. 2
ENGLISH
150-
1520
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
release
desired button
release
desired button
release
desired button
release
desired button
If cancelled
ok
If not present
KO
If clone, it is disabled
dis
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
Activation of edge input in BARC closure
BARc
Activation of edge input in BARO opening
BARo
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
Activation of OPEN input with cpr logic set to 1 (OPEN
Cpr1
command priority)
Restoring of factory settings in progress
rst
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
At the end of an opening or closing manoeuvre the use
of thermal resources utilised by the motor to perform the
movement gets signalled (03 means 3%). Upon reaching
TH03
100%, the thermal protection is triggered, impeding the
movement until the motor is cooled.
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
ER70-ER71
Internal system supervision control error.
ER74-ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
ER73
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ok
Con rm/Switch on display
Scroll down
• Opening command
• ≥ 2 sec Manual transmitter programming as start
• Closure command
• ≥ 2 sec Manual transmitter programming as 2nd radio chan-
nel
(FIG. I)
• ≥ 5 sec Cancellation of remote controls
20 2126 27
• Access menu
• ≥ 5 sec end stop adjustment menu + autoset (FIG. G)
DESCRIPTION
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
Check safety edge connection and/or parameter/
logic settings
- Check connections to motor
- Hardware problems with board (contact techni-
cal assistance)
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again.
If the problem persists, contact the technical as-
sistance department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
ters and Logics)
Pressing OK, the board will keep on working with
D-track as a default.
1520
prg
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
8888
Scroll up
8888
Exit Menù
20 2126 27
50 515260 6162
20 2126 27
50 515260 6162
NOTES
The board settings must be checked (Parame-
An autoset is required
(FIG. I)
70 7172 73
70 7172 73
(FIG. K)
ARGO BT A 20-35 - 21
loading

Este manual también es adecuado para:

Argo bt a 35