Robern PORTRAY ELECTRIC UPGRADE Instrucciones De Seguridad Importantes página 9

Compatible con: pl portray series cabinets p2c16, p2c20, p2c24
INSTALLATION
DANGER - RISK OF SHOCK - DISCONNECT
POWER BEFORE INSTALLATION
All wiring should be done by a qualified licensed electrician.
WARNING: To reduce the risk of electrical shock, shut off power before wiring the electrical box.
CAUTION: Requires 120 VAC 20 Amp GFI protected circuit.
CAUTION: This product must be connected to a grounded, metal permanent wiring system,
or an equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment grounding terminal or lead on the product.
WARNING: Electrical box must be wired to a 20 Amp GFI (Ground Fault Interrupter)
protected circuit when used in bathrooms and all other locations required by the National
Electric Code.
ATTENTION: Verify that all power is removed from the source power wires before proceeding.
4. Strip outer jacket of the romex wire, exposing 2-3" of the White, Black, and Ground Wires.
Pull power wire through opening in cabinet and through wire grommet in mounting bracket
about 2-3" or until the outer jacket of the source power wire just protrudes through the
Romex connector.
Secure the mounting bracket removed in Step 1 to the cabinet using the two supplied
#8-32 x 1/4" screws [203-1285].
©2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
Part no. CB-209-1346 09/23/20
800.877.2376
www.robern.com