Technical Specifications - Lincoln Electric INVERTEC PC208 Manual De Instrucciones

Ocultar thumbs Ver también para INVERTEC PC208:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

Technical Specifications

Input Voltage
230 V ±10%
Single Phase
Duty Cycle
(Based on a 10 min. period)
100%
60%
35%
Cutting Current Range
10 - 25 A
Required Inlet Flow Rate
PC210
80 ±20% l/min @ 5.0bar
Fuse (delayed) or Circuit Breaker ("D"
characteristic) Size
16 A
Height
385 mm
Operating Temperature
-10°C to +40°C
INPUT
Input Power at Rated Output
2 kW @ 100% Duty Cycle
2.5 kW @ 60% Duty Cycle
3 kW @ 35% Duty Cycle
RATED OUTPUT AT 40°C
Output Current
OUTPUT RANGE
Maximum Open Circuit Voltage
500 Vdc
EXTERNAL INLET COMPRESSED AIR
RECOMMENDED INPUT CABLE AND FUSE SIZES
Type of Plug
(Included with Machine)
SCHUKO 16A / 250V or
AUSTRALIAN 15A / 250V
PHYSICAL DIMENSIONS
Width
215 mm
15 A
20 A
25 A
Required Inlet Pressure
PC210
Length
(case only,without torch)
480 mm
Storage Temperature
A-6
Frequency
50Hz
Output Voltage
86 Vdc
88 Vdc
90 Vdc
Pilot Arc Current
10 A
6.0bar - 7.5bar
Input Power Cable
3 Conductor, 1.5 mm
Weight
18 – 18.5 kg
-10°C to +40°C
2
Tabla de contenido
loading

Este manual también es adecuado para:

Invertec pc210

Tabla de contenido