Technical Data
Code
Description
Voltage
Frequency
Motor Power
Current
Maximum Pressure
Speed
Continuous Air flow
Tank Capacity
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power Requirements
WARNING
In the event of fault or breakdown, the ground connection delivers a
trajectory with minimum resistance for power, thus reducing the risk of electric shock.
This tool is equipped with a power cable with a ground conductor and a ground plug.
The plug shall be connected into a power input set up and grounded in accordance to
all the local codes.
CAUTION
Using electric extensions for compressors is not recommended. Its use causes voltage drop, losing power
in the motor and overheating. In place of an extension increase the scope of action in the compressor by connecting a hose
with higher outlet length. Connect additional lengths of hose as needed. Likewise, if in need of using a pneumatic tool
outdoors with humid environment or even rain, you can operate the compressor indoors away from humidity and operate
the power tool connected to the compressor using additional lengths of hose without the risk of electric shock.
• In the event of connecting the compressor into a fuse protected circuit, use delay action fuses Type D.
WARNING
This equipment
SHOULD BE USED
with 115 V ˜ - 127 V ˜ , using a
DIFFERENT VOLTAGE WILL
SERIOUSLY DAMAGE
the product.
COMP-50LV
19360
Air Compressor
127 V
60 Hz
Rated: 2 1/2 Hp Maximum: 3 1/2 Hp
12 A
116 PSI
3 450 RPM
4.4 CFM - 40 PSI
3.4 CFM - 90 PSI
13.2 Gal
14 AWG x 3C with 221 °F insulation temperature
Class I
Power Cord Grips used in this product: Type Y.
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class B