Above the maximum temperature, the life of the compressor is shortened and the production is substantially lower.
Do not place anything over the maker or facing the front louver.
In case the front louver is not enough, the exit is either total or partially obstructed or due to its placement, it will receive
hot air from another device, we strongly recommend, in case it is not possible to change the location of the machine, to
install a water condenser.
IT IS IMPORTANT THAT THE WATER PIPING DO NOT PASS BY OR NEAR SOURCES OF HEAT SO AS NOT TO LOSE ICE
PRODUCTION.
IMPORTANT: Thread the support legs to the base of the machine on the housing set to such end, in case of machines
having this feature, and regulate the height as to have the equipment perfectly leveled.
MINIMUM DISTANCE TO OBSTACLES
Side View
>75cm / >29"
* There's no minimum distance to obstacles in the sides of the machine
CONNECTION DIAGRAM
FOR COMPACT MODELS
Plug
>10cm / >4"
>10cm / >4"
FOR MODULAR MODELS
>10cm
>4"
Socket
Tap
Water Connection Hose
Discharge Hose
3
USER MANUAL IQ
>10cm
>4"
Plug
Socket
Tap
Water Connection Hose
Condensar Discharge Outlet
Bin Drainage