5
5.1
1
2
3
Materials in contact with chemical
1 Multifunction valve
2 Hose clamp
Housing: PVDF
3 Flow Control
Float:
Fig. 2
Seals:
Screw the Flow Control directly onto the pump discharge valve (is the
adjustment knob facing the operator?).
5.2
Plug the flow monitor connector into the "flow monitor" socket on the pump
(symbol
The description "Flow" will now appear in the bottom left of the LCD display
of the gamma/ L. If not, switch from OFF to ON in the FLOW-menu and set
the number of permitted failed strokes (the FLOW-menu is only accessible, if
the connector is plugged into the "flow monitor" socket).
ProMinent
®
Installation
Installation, hydraulic
NOTICE
• In the case of the pump types 0413, 0220, 0420, 0713 and
0232, if a hose is used on the discharge side, fit this near
the liquid end or fit the Flow Control.
Strong vibrations may otherwise occur which will damage
the liquid end.
• If a multifunction valve is screwed to the Flow Control,
secure with a hose clamp (see figure)!
Strong vibrations may otherwise occur which will damage
the liquid end.
• The Flow Control must never exceed the maximum
admissible operating pressure of 16 bar, irrespective of
the operating status of the system.
• The Flow Control must always be used in the vertical
position!
• Fit a foot valve to the suction side of the pump.
Sediments in the Flow Control can obstruct the float.
• When metering aggressive chemicals check the resistance
of the materials used (see ProMinent resistance list in the
latest product catalogue or at www.prominent.de)!
PTFE coating
FPM-B or EPDM (depending on order no.)
Installation, electric
).
Installation
19