2. Place a container under the drain hole. Then, using a 5/16
in. (8 mm) hex key, unscrew the oil cap (with the dipstick
attached) and tilt the log splitter forwards to allow the oil
to drain from the tank (Fig. 8).
Drain
plug
Container
3. Tilt the log splitter up vertically and place a funnel into the
drain hole. Then fill the hydraulic tank with new AW32
anti-wear hydraulic oil (Fig. 9).
Fig. 9
Hydraulic oil
4. To check the oil level, wipe the dipstick with a cloth, and
with the log splitter tilted vertically, insert the dipstick fully
into the drain plug, then pull it back out. The oil residue
should sit between the top notch indicating full oil level,
and the bottom notch indicating low oil level (Fig. 10).
Fig. 10
Fig. 8
Dipstick
Oil cap
Storage
• Remove the batteries from the tool before storing.
• Store the tool and its accessories in a dry, frost-free, and
well-ventilated place out of the reach of children.
• The ideal storage temperature is between 50ºF (10°C) and
86ºF (30°C).
Battery + Charger Storage
• Store the battery packs and charger at room temperature
and away from moisture. Do not store in damp locations
where corrosion of terminals may occur.
Funnel
• Permanent damage may occur if the battery packs are
stored for extended periods of time at high temperatures
(over 105ºF/40.5ºC).
• Unplug the battery charger and battery packs when not in
use. Recharge the battery packs every 6 months to 50%
capacity to maintain optimal battery performance.
Battery Caution + Disposal
Always dispose of your battery packs according to federal,
state, and local regulations. Contact a recycling agency in your
area for recycling locations.
m
CAUTION!
some energy. Before disposing, use electrical tape to cover the
terminals to prevent the battery pack from shorting, which may
cause a fire or explosion.
m
WARNING!
never burn or incinerate a battery pack even if it is damaged,
dead, or completely discharged. When burned, toxic fumes
and materials are emitted into the surrounding environment.
10
Dipstick
Full oil level
Low oil level
Even discharged battery packs contain
To reduce the risk of injury or explosion,